Cylinders
จุดเด่นของ SHUT-OFF VALVES – 19E*.A.00.MF
- Non-return valves that can close the suction line in the event of air leakage from the suction cup that is not located on the workpiece or not fully adherent to it.
จุดเด่นของ SHUT-OFF VALVES WITH CONTROLLED LEAKEGE LOSS – 19E*.A.*.MF
- Non-return valves that can close the suction line in the event of air leakage from the suction cup that is not located on the workpiece or not fully adherent to it.
Air distribution
- 3/2 N.C. poppet valve for opening and exhausting the circuit
- Allows to pneumatically supply the part of the system downstream of the valve
- Manual adjusting lockable handle (in shut-off position) with a maximum of three pad-locks
- Atex certification (II 2GD o II 3GD) on request
Air distribution
- 3/2 N.C. poppet valve for entering and exhausting the circuit
- It allows to pneumatically supply the part of the system downstream of the valve
- Opening and closing of the valve via solenoid operator
- The supply pressure must be minimum 2 bars or higher
- It is possible to produce the external supplied solenoid version by mounting the 305.10.05 between the valve main body and the solenoid pilot valve.
- The air supply can only be done via port 1
- Ensure that the downstream air consumption will not cause a pressure drop which could result in the pressure falling below the minimum operating values.
- If the pressure inside the valve falls below 2 bars, the valve might shut off.
- Atex certification (II 2GD o II 3GD) on request
Air distribution
- 3/2 N.C. poppet valve for entering and exhausting the circuit
- It allows to pneumatically supply the part of the system downstream of the valve
- Opening and closing of the valve via solenoid operator
- The supply pressure must be minimum 2 bars or higher
- It is possible to produce the external supplied solenoid version by mounting the 305.10.05 between the valve main body and the solenoid pilot valve.
- The air supply can only be done via port 1
- Ensure that the downstream air consumption will not cause a pressure drop which could result in the pressure falling below the minimum operating values.
- If the pressure inside the valve falls below 2 bars, the valve might shut off.
- Atex certification (II 2GD o II 3GD) on request
Pneumatics and Process Interfaces
Burkert – Type MKRS – Redundancy Valve Block for Safety Related Shut-Off Function
จุดเด่นของ Type MKRS
- DIN-rail mounting
- Pressure switch included
- Redundancy functions possible
ROSS Controls® Products
- High-speed poppet construction
- Constant repeatability
- Non-friction Viton seals on metal seats
- Non-lube
- Specialized low-wear body coating
- Blowhead compatible
- Separate Kick-Off valve available
- Built-in flow controls and inlet shut-off
- Built-in pressure boosters
- Special base and two signal options
You must be logged in to post a comment.