3/2 way pneumatic cartridge solenoid valve
DOWNLOAD CATALOG (ดาวน์โหลดแคตตาล็อก)
General Technical Data
Product properties |
|
Dimensions | Detailed information can be found in chapter “4. Dimensions” on page 6. |
Material | |
Seal | FKM |
body | PEEK |
Further materials in contact with the medium | PA, LCP, MS, Edelstahl… Detailed information can be found in chapter “3.2. Material specifications” on page 5. |
Permissible leakage | Vac…10 bar (dependent on the version used)1.) |
Weight | 6 g (standard version) |
Nominal diameter | DN 0.5 / DN 0.8 / DN 1.0 / DN 1.2 |
Switching function | Detailed information can be found in chapter “2. Circuit functions” on page 4. |
Typical product service life | 100.000,000 switching cycles (accordance to endurance tests)2.) |
Performance data |
|
Pressure range | DN 0.5 (Vac…9 bar)1.) / DN 0.8 (Vac…7.5 bar)1.) / DN 1.0 (Vac…5 bar)1.) / DN 1.2 (Vac…1.5 bar)1.) |
Switching times | Opening: < 5 ms (pressure rise 0…10 %) Closing: < 5 ms (pressure drop 100…90 %) |
Electrical data |
|
Operating voltage | 12 or 24 V DC (other voltages on request) |
Voltage tolerance | ± 10 % |
Power consumption | 0.7 W 2.8 W/0.3 W (with external electric power reduction) 0.3 W (for explosion proof version) |
Duty cycle | 100 % ED continuous rating |
Switching frequency | 16 Hz |
Switching noise | 42 dB |
Medium data |
|
Standard version FKM | – 10 °C…+ 55 °C |
Low temperature version FKM | -20 °C…+ 55 °C (on request |
Operating medium | Neutral gases |
Approvals and certificates |
|
Protection class | IP65 with flying leads and cable plug Type 1054 IP30 with Rectangular plug Type 2505 |
Process/Port connection & communication |
|
Port connection | Bürkert Cartridge Connection |
Electrical connection | Plug/Solder, flying leads |
Approvals and certificates |
|
Explosion proof (on request) Detailed information can be found in chapter “6.1. Electrical data for the Exi version” on page 10. |
|
BVS 16 ATEX E 088 X | I 2G Ex ib IIC T6…T4 Gb II 2D Ex ib IIIB T155 °C Db |
IECEx BVS 16.0053 X | Ex ib IIC T6…T4 Gb Ex ib IIIB T155 °C Db |
Conformity (on request) | UL class 2 Oxygen compatible |
Pins | IP00 |
Special plug | IP40 |
Flying leads | IP54 |
Environment and installation |
|
Installation position | As required |
Standard version FKM | – 10 °C…+ 55 °C |
Low temperature version FKM | -20 °C…+ 55 °C |
สอบถามข้อมูลเพิ่มเติม ติดต่อเรา :
02-384-6060 (อัตโนมัติ) [email protected] บริษัท ฟลูเทค จำกัด Flu-tech @flutech.co.th