Plunger valve 3/2 way direct-acting
Burkert type 6014 is a direct-acting plunger valve. The stopper and plunger guide tube are welded together to enhance pressure resistance and leak-tightness. Various seal material combinations are available depending on the application. A Bürkert-specific flange design (SFB) enables space-saving arrangement of valves on a manifold. The coils are moulded with polyamide or with chemically resistant epoxy. Pulse coils are available for the reduction of electrical power consumption during operation. Optional manual actuation enables quick commissioning and easy maintenance.
DOWNLOAD CATALOG (ดาวน์โหลดแคตตาล็อก)
BURKERT TYPE 6014 สามารถใช้ได้ร่วมกับ
General Technical Data | Burkert – Type 6014
Product Properties | ||
Dimensions | Detailed information can be found in chapter “5. Dimensions” on page 8. | |
Seal Material | FKM (EPDM on request) | |
Body Material | Brass or stainless steel, polyamide (sub-base) | |
Coil Material | Polyamide (Epoxy on request) | |
Nominal Diameter | DN1.5...DN2.5 | |
Thermal insulation class of solenoid | Polyamide class B (Epoxy class H on request) | |
Circuit function | C, D and T (see “2. Circuit functions” on page 4) | |
Electrical data | ||
Operating voltage | 24 V DC, 24 V/50 Hz, 230 V/50 Hz (other voltages on request) | |
Voltage tolerance | ±10% | |
Performance Data | ||
Duty cycle / single valve assembly | 100 % continuous rating / Intermittent operation 60 % (30 min) or with 5 W coil (on request) | |
Medium data | ||
Operating medium | Neutral gases and fluids (e.g. compressed air, town gas, natural gas, water, hydraulic oil, petrol). Suitable for technical vacuum. | |
Medium temperature | - 10 °C... + 100 °C (PA coil) / - 10 °C... + 120 °C (Epoxy coil) | |
Viscosity | Max. 21 mm2/s | |
Process/Port connection & communication | ||
Electrical connection | DIN EN 175 301- 803 Form A for cable plug Type 2518 (see “9.4. Ordering chart ac- cessories” on page 24) / ATEX/IECEx version with 3 m moulded cable | |
Port connection | G 1⁄8, G 1⁄4, sub-base (SFB) | |
Environment and installation | ||
Installation position | Any, preferably actuator upright | |
Ambient temperature (max.) | Max. + 55 °C |
*For selecting the correct product please refer to the technical data, images and notes for proper use according to the data sheet, or contact Flu-Tech directly.