General Technical Data
Sizes 8 to 30
Pilot Solenoids |
Two, rated for continuous duty. Standard voltages: 100-110 volts 50 Hz.; 100-120 volts 60 Hz.; 24, 110 volts DC. Other voltages available.
|
Power Consumption
|
Each solenoid, 87 V A inrush, 30 V A holding on 50 or 60 Hz.; 14 watts on DC |
D-S Monitor
|
Uses same voltage and frequency as pilot solenoids, but power supply must be independent and continu- ous. Standard Voltages: 100, 110 volts 50 Hz; 100, 120 volts 60 Hz; 24 volts DC (no other voltages available for D-S). |
Ambient Temperature | 40° to 120°F (4° to 50°C) |
Media Temperature
|
40° to 175°F (4° to 80°C) |
Flow Media
|
Filtered air. 5 micron recommended
|
Pressure Range
|
30 to 125 psig (2 to 8.5 bar)
|
Size | Port Size |
Average Cv
|
Valve Model Numbers
|
Dimensions inches (mm) | Weight lb. (kg.) | ||||
In-Out | Out-Exh. |
w/ Overrides
|
w/o Overrides
|
A | B | C | |||
8 | G 1/2 | 3.5 | 8.5 |
8.5 (216)
|
7.2 (184)
|
16.5 (418)
|
16.8 (7.6)
|
||
8 | G 3/4 | 4.0 | 12 |
8.5 (216)
|
7.2 (184)
|
16.5 (418)
|
16.8 (7.6)
|
||
12 | G 3/4 | 8.0 | 15 |
9.0 (229)
|
8.6 (219)
|
17.8 (451)
|
20.5 (9.2)
|
||
8 | G 1 | 4.0 | 12 |
8.5 (216)
|
7.2 (184)
|
16.5 (418)
|
16.8 (7.6)
|
||
12 | G 1 | 8.5 | 19 |
9.0 (229)
|
8.6 (219)
|
17.8 (451)
|
20.5 (9.2)
|
||
12 | G 1-1/4 | 9.0 | 21 |
9.0 (229)
|
8.5 (216)
|
17.8 (451)
|
20.5 (9.2)
|
||
30 | G 1-1/4 | 20 | 42 |
12.4 (314)
|
11.1 (282)
|
21.8 (553)
|
39.3 (17.7)
|
||
30 | G 1-1/2 | 21 | 43 |
12.4 (314)
|
11.1 (282)
|
21.8 (553)
|
39.3 (17.7)
|