Showing 2115–2121 of 4536 results

  • For use in gravity systems.
  • Capacity: 10 oz (0.3 l) 7,970 drops
  • Maximum Temperature: 125º F
  • One drop = 1/30 cc. Capacity in drops is at 90% of full capacity.

จุดเด่นของ V10 Sentry Slide 1/8, 1/4 and Tube Fittings

  • 3 Way lockout valve specifically for use with Sentry FRLs
  • Threaded ports or quick-connect fittings for tubing up to 10 mm in diameter
  • Available pre-assembled on FRL assembly, or as a single component for retrofitting in the field
  • Can be padlocked only in the closed position
  • Slide moves smoothly even after long period on standby
  • NPTF port threads; optional BSPP threads or tube fittings

Accessories, Brackets, Gauges and Valves

Master Pneumatic – V35 Guardsman Sleeve 1/4, 3/8, 1/2 and 3/4

จุดเด่นของ V35 Guardsman Sleeve 1/4, 3/8, 1/2 and 3/4

  •  3-Way lockout valve specifically for use with GUARDSMAN FRLs
  • Each unit has a safety yellow barrel and a caution red slide
  • Can be padlocked only in the closed position
  • Sleeve rotates for most convenient location of padlock
  • Sleeve moves smoothly even after long period on standby
  • Controlled exhaust rate muffles exhaust noise
  • NPTF port threads; optional BSPP threads.

จุดเด่นของ V380 Manual Control Lockout Valve

  • Modular or inline mounting.
  • Provides positive lockout of supply air and exhausting of downstream air.
  • Provides delayed pressure buildup for safe starts.
  • 3-Port valve.
  • Can be padlocked only in the closed position.
  • NPTF port threads; optional BSPP threads.

จุดเด่นของ V382 Manual Control High Flow/Exhaust Lockout Valve

  • High flow threaded exhaust port to accommodate muffler or a line for remote exhausting.
  • Compact modular (Series 380 and CFR360 / 370) or inline
  • Optional slow start (delayed-pressure-buildup) function
  • 3 ported valve
  • NPTF port threads:  Optional BSPP Threads
  • 1/8” downstream pressure ports
  • Options available to indicate downstream pressure
  • Carboxilated Buna O-Rings & Acetal Slide for low break away friction, even after a long standby period
  • PUSH to close, PULL to open.
  • Preferred installation is downstream of F-R-L.  NOTE:  If installed upstream of regulator, the regulator must be capable of Quick Exhaust (reverse flow)
  • LOTO (Lockout Tag out). Can be padlocked only in the closed position.

จุดเด่นของ V383 Manual Control High Flow/Exhaust

  • High flow threaded exhaust port to accommodate muffler or a line for remote exhausting.
  • Compact modular (Series 380 and CFR360 / 370) or inline
  • Optional slow start (delayed-pressure-buildup) function
  • 3 ported valve
  • NPTF port threads:  Optional BSPP Threads

Accessories, Brackets, Gauges and Valves

Master Pneumatic – V40 High Flow Vanguard Manual 1-1/2 and 2

จุดเด่นของ V40 High Flow Vanguard Manual 1-1/2 and 2

  • Easily identified by unique shap
  • Lockable only in the OFF positio
  • Large exhaust port for rapid release of pressure
  • Special Teflon seals help to ensure "shift-ability" even after long periods of non-use
  • Positive action (2 positions only)
  • Simple push/pull of the large red handle provides direct manual operations
  • Pressure sensing port allows installation of either the popup indicator or pressure switch to verify pressure downstream to the next obstruction is released
  • NPTF port threads; optional BSPP threads