Full bore magmeter without flanges (wafer version)
The flowmeter Type 8054, which consists of a sensor Type S054 (compact or remote variant) connected to the electronics assembly Type SE56 (without a display in the compact variant or with a display in the compact or remote variant), is designed for liquids with a minimum conductivity of 5 μS/cm. Combined with a dosing valve, the flowmeter Type 8054 can also be used for high-precision filling and dosing procedures.
DOWNLOAD CATALOG (ดาวน์โหลดแคตตาล็อก)
TYPE 8054 สามารถใช้ได้ร่วมกับ
General Technical Data
Product properties |
|
Sensor housing | Carbon steel painted (stainless steel 304 or 316 on request) |
Electrode | Stainless steel 316L (Alloy C, Titanium, Tantalum, Platinum-rhodium on request) |
Lining | PP or ebonite (hard rubber) (PTFE on request) |
Seal | • FKM (EPDM on request) with PP lining • Without gasket with ebonite (hard rubber) lining (with PTFE lining on request) |
Pipe diameter | DN 25…DN 200 (upper DN on request) |
Dimensions | Detailed information can be found in chapter “3. Dimensions” on page 6. |
Measuring principle | Electromagnetic induction Detailed information can be found in chapter “5.1. Measuring principle” on page 9. |
Measuring range | 0…0.72 m3/h to 0…1130 m3/h Detailed information can be found in chapter “6.4. Ordering chart sensor Type S055” on page 11. |
Performance data |
|
Measurement deviation | If used with SE56 transmitter: •in standard compact version: ± 0.2 % of reading •in standard remote version: ± 0.2 % of reading •in Basic compact version: ± 0.8 % of reading •in compact version without display: ± 0.2 % of reading |
Repeatability | If used with SE56 transmitter: • in standard compact version: ± 0.1 % • in standard remote version: ± 0.1 % • in Basic compact version: ± 0.2 % • in compact version without display: ± 0.1 % |
Vacuum resistance | 200 mbar (2.9 PSI) absolute at 100 °C (212 °F) |
Medium data |
|
Fluid temperature | •With PP lining used with SE56 transmitter: – in standard compact version: – 0…+ 60 °C (+ 32…+ 140 °F) – in standard remote version: – 0…+ 60 °C (+ 32…+ 140 °F) – in Basic compact version: – 0…+ 60 °C (+ 32…+ 140 °F) – in compact version without display: – 0…+ 60 °C (+ 32…+ 140 °F) •With PTFE lining (on request) used with SE56 transmitter: – in standard compact version: – 20…+ 100 °C (- 4…+ 212 °F) – in standard remote version: – 20…+ 130 °C (- 4…+ 266 °F) – in Basic compact version: – 10…+ 100 °C (+ 14…+ 212 °F) – in compact version without display: – 20…+ 100 °C (- 4…+ 212 °F) |
Fluid pressure | PN 16 (232 PSI) with PP lining |
Minimum conductivity | 5 µS/cm (or 20 µS/cm with demineralised water) |
Process/Port connection & communication |
|
Process connection | Wafer |
Electrical connection | 2 cable glands PG9 (for remote version of the sensor) |
Approvals and certificates |
|
Degree of protection according to IEC/EN 60529 | If used with SE56 transmitter: • in standard compact version: IP65 and IP67 • in standard remote version: – IP65 – IP68 (if the junction box of the sensor is filled with resin) • in Basic compact version: IP65 • in compact version without display: IP65 and IP67 |
CE directives | The applied standards, which verify conformity with the EU Directives, can be found on the EU Type Examination Certificate and/or the EU Declaration of conformity (if applica-ble). |
Pressure equipment directives | The device is subject to the requirements of the Pressure Equipment Directive 2014/68/EU. Category II device for group 1 and 2 fluids under the following conditions: • maximum allowable pressure (PS) ≤ 40 bar • minimum/maximum temperature (TS): – 10/+ 130 °C • within the following limits for liquids of group 2: – PN 10 for DN 400…DN 500 – PN 16 for DN 250…DN 300 – PN 25 for DN 200…DN 250 – PN 40 for DN 40…DN 250 • within the following limits for liquids of group 1 with a vapour pressure at the maxi-mum allowable temperature not exceeding 0.5 bar (g): for diameters above DN 25 and PS x DN > 2000 |
Environment and installation |
|
Ambient temperature | If used with SE56 transmitter: • in standard compact version: – 20…+ 60 °C (- 4…+ 140 °F) (operation and storage) • in standard remote version: – 20…+ 60 °C (- 4…+ 140 °F) (operation and storage) • in Basic compact version: – 10…+ 50 °C (+ 14…+ 122 °F) (operating) – 20…+ 50 °C (- 4…+ 122 °F) (storage) • in compact version without display: – 20…+ 40 °C (- 4…+ 104 °F) (operation and stor-age) |
Relative air humidity | ≤90%,withoutcondensation |
Height above sea level | Max.2000 m |
Operating condition | Continuous |
Equipment mobility | Fixed device |
Application range | Indoorandoutdoor(protectthedeviceagainstelectromagneticinterference,ultravioletrays andagainsttheeffectsofclimaticconditions) |
Installation category | Category II according to UL/EN 61010-1 |
Pollution degree | Degree 2 according to UL/EN 61010-1 |
*For selecting thecorrect product please refer to the technical data, images and notes for proper use according to the data sheet, or contact Flu-Tech directly.
สอบถามข้อมูลเพิ่มเติม ติดต่อเรา :
02-384-6060 (อัตโนมัติ) [email protected] บริษัท ฟลูเทค จำกัด Flu-tech @flutech.co.th