Transmitters for electromagnetic inductive flow sensor
The transmitter Type SE58 (in S, M or L variant) combined with the electro-magnetic flow sensor (in compact or remote variant) Type S051, S054, S055 or S056 is designed for applications with a minimum conductivity of 5 μS/cm.
DOWNLOAD CATALOG (ดาวน์โหลดแคตตาล็อก)
TYPE se58 สามารถใช้ได้ร่วมกับ
General Technical Data
Performance data |
|
Measurement deviation | ≤ ± 0.8 % of the measured value (optional: ± 0.4 % of the measured value) for flow velocity >0.5 m/s Detailed information can be found in chapter “3.1. Measurement deviation diagram” on page 13. |
Repeatability | ≤ ± 0.4 % of the measured value (optional: ± 0.2 % of the measured value) for flow velocity |
Response time | Minimum time • for analogue output (AO), when damping setting is deactivated and according to sensor size: – DN 03…DN 250: 20 ms – DN 300…DN 400: 100 ms • for digital output: 100 ms (no matter the sensor size) |
Electrical data |
|
Operating voltage | • 100…240 V AC, 44 Hz…66 Hz • 12…48 V DC • Others on request |
Power consumption | Max. 20 VA with 100…240 V AC operating voltage |
Input | 1 digital, function use is configurable (e.g. Totalizer reset) |
Output | • Transistor: 2 digital outputs (DO), both with open collector configurable as – pulse/frequency (1250 Hz, max. 100 mA, 30 V DC) or – alarm/batch (adjustable usage) • Current: – max. 2 analogue outputs (AO), 0/4…20/22 mA, RL = 1000 Ω – HART (optional) only over first analogue output • Serial interface (optional): RS-485 (available with Modbus protocol (option)) |
Galvanic isolation | All the input/outputs are galvanically isolated up to 250 V from operating voltage |
Protection class | Class I |
Sensor/transmitter connection cable | Sensor/transmitter connection cable Cable C015/C016 for remote version, 10 m (other lengths on request) |
Medium data |
|
Velocity range | 0.4…10 m/s |
Minimum conductivity | 5 μS/cm |
Connections & communication |
|
Electrical connection | • 5 cable glands PG11 for aluminium or nylon housing or • 6 cable glands PG11 for stainless steel housing |
Plug for configuration connection | USB port for the connection to PC (USB cable with USB mini B and USB type A connectors is required for the configuration and parameter settings) |
Industrial communication | • RS-485 • Wi-Fi (as alternative for remote device configuration) |
Protocol | • Modbus over RS-485 • HART (available on first analogue output) |
Approvals and certificates |
|
CE directive | The applied standards, which verify conformity with the EU Directives, can be found on the EU Type Examination Certificate and/or the EU Declaration of conformity (if applicable). |
Environment and installation |
|
Ambient temperature | Operation and storage • Aluminium or stainless steel housing: – 20…+ 60 °C (- 4…+ 140 °F) • Reinforced nylon housing: – 10…+ 50 °C (+ 14…+ 122 °F) |
Relative air humidity | 0…100 %, without condensation |
Height above sea level | – 200…+ 4000 m |
Operating condition | Continuous |
Equipment mobility | Fixed device |
Application range | Indoor and outdoor (protect the device against electromagnetic interference, ultraviolet rays and against the effects of climatic conditions) |
Degree of protection according to IEC/EN 60529 | • Aluminium housing: IP65, IP67 (IP 68 option) • Reinforced nylon housing: IP65, IP67 • Stainless steel housing: IP65 |
Installation category | Category II according to UL/EN 61010-1 |
Pollution degree | Degree 2 according to UL/EN 61010-1 |
*For selecting thecorrect product please refer to the technical data, images and notes for proper use according to the data sheet, or contact Flu-Tech directly.