The Bürkert Type S012 fitting for paddle wheel sensors can be combined with Type SE11 p and Type SE12 paddle wheel transmitters with magnetic measuring principle for flow measurement.
DOWNLOAD CATALOG (ดาวน์โหลดแคตตาล็อก)
BURKERT TYPE S012 สามารถใช้ได้ร่วมกับ
Product Properties |
|
Non wetted parts – Housing material
|
PPS
|
Non wetted parts – Seal material | EPDM |
Non wetted parts – M12 male fixed plug material | Stainless steel A4 |
Non wetted parts – Cable gland with 1 m connected cable material (Availble on request) | PA |
Wetted parts – Fitting material | PVC (cable) and PA (cable gland) |
Wetted parts – Seal material |
Brass, stainless steel 1.4404/316L, PVC or PP FKM (EPDM option)
|
Wetted parts – Axis and bearings material | Ceramics (Al2O3) |
Wetted parts – Paddle wheel, holder material | PVDF (blue for paddle wheel) |
Dimensions |
Detailed information can be found in chapter “4. Dimensions” on page 6.
|
Measuring element
|
Magnetic hall sensor |
Compatibility |
Transmitter Type SE11 compatible with Bürkert fitting Type S012
|
Pipe diameter |
DN 06…DN 50 (DN 65 on request)
|
Measuring range | Flow rate: 0.5…1000 l/min (0.13…265 gpm) / Flow velocity: 0.3…10 m/s |
Performance Data |
|
Measurement deviation
|
Teach-In: ±1% of the measured value (at Teach-In flow rate value) / Standard K-factor: ±2.5% of the measured value
|
Linearity |
±0.5% of full scale
|
Repeatability |
±0.4% of the measured value
|
Electrical Data |
|
Operating voltage
|
One pulse output version: 4.5…24 V DC, filtered and regulated / Two pulse outputs version: 6…36 V DC, filtered and regulated / Connection to main supply: permanent (through external SELV (Safety Extra Low Volt- age) and LPS (Limited Power Source) power supply)
|
Power Source (not supplied) |
Limited power source according to UL/EN 60950-1 standards or limited energy circuit according to UL/EN 61010-1 §9.4
|
DC reverse polarity protection |
Yes
|
Over-voltage protection | Yes |
Current consumption | <5 mA (without load) |
Outputs | One pulse output version: Transistor NPN, open collector / Two pulse outputs version: Transistor: NPN or PNP, open collector |
Voltage supply cable
|
Max. 1.5 mm2 cross-section
|
Medium Data |
|
Fluid temperature
|
With fitting in: • PVC: 0…+ 60 °C (+ 32…+ 140 °F) • PP: 0…+ 80 °C (+ 32…+ 176 °F) • Stainless steel or brass: – 15…+ 100 °C (+ 5…+ 212 °F) (if T°ambient ≤ + 45 °C) or -15…+90 °C (+5…+194 °F) (if +45 °C ≤ T°ambient ≤+60 °C) |
Fluid pressure
|
Max. PN 10 (145 PSI) with plastic fitting • Max. PN 16 (232 PSI) with metal fitting Detailed information can be found in chapter “5.1. Pressure temperature diagram” on page 8. |
Viscosity
|
Max. 300 cSt
|
Rate of solid particles | Max. 1% |
Maximum particle size | 0.5 mm |
Process/Port Connection & Communication |
|
Port connection
|
• Metal: Internal or external thread (weld ends, clamp or flange on request) • Plastic: True union with nut and solvent socket, external thread (spigot on request) |
Electrical connection | 5 pin M12 male fixed plug or with 1 m cable via cable gland |
Approvals and Certificates |
|
Standards – Degree of protection according to IEC/ EN 60529 |
IP67 with device wired and M12 cable plug mounted and tightened / IP65 with cable gland
|
CE directives |
The applied standards, which verify conformity with the EU Directives, can be found on the EU Type Examination Certificate and/or the EU Declaration of conformity (if applicable)
|
Pressure equipment directives |
Complying with Article 4, Paragraph 1 of 2014/68/EU directive
|
Certificate | On request: • Inspection certificate 3.1 (acc. to EN-ISO 10204) • Test report 2.2 (acc. to EN-ISO 10204) • Certification of conformity for the surface quality DIN4762-DIN4768-ISO/4287/1 • 3 points flow calibration certificate |
Environment and Installation |
|
Ambient temperature
|
Operation and storage: – 15…+ 60 °C (+ 5…+ 140 °F)
|
Relative air humidity | ≤80%, without condensation |
Height above sea level |
Max. 2000 m
|
Operating condition | Continuous |
Equipment mobility | Fixed |
Application range |
Indoor and outdoor (Protect the device against electromagnetic interference, ultraviolet rays and against the effects of climatic conditions)
|
Installation category | Category I according to UL/EN 61010-1 |
Pollution degree | Degree 2 according to UL/EN 61010-1 |
Type 8012
Product Properties |
|
Non wetted parts – Housing material | PPS |
Non wetted parts – Seal material | EPDM |
Non wetted parts – Screws material | Stainless steel A4 |
Non wetted parts – M12 male fixed plug material | PA |
Non wetted parts – Cable gland with 1 m connected cable (on
request) material |
PVC (cable) and PA (cable gland) |
Wetted parts – Fitting material |
Brass, stainless steel 1.4404/316L, PVC or PP |
Wetted parts – Seal material | FKM (EPDM option) |
Wetted parts – Axis and Bearings material |
Ceramics (Al2O3) |
Wetted parts – Paddle wheel, holder material | PVDF |
Dimensions |
Detailed information can be found in chapter “4. Dimensions” on page 6. |
Measuring element |
Optical – infra-red (or magnetic paddle wheel, on request) |
Compatibility | Electronic module (Type SE12) compatible with Bürkert fitting (Type S012) |
Pipe diameter |
DN06…DN50 (DN65 on request) |
Measuring range | Flow rate: 0.5…1000 l/min (0.13…265 gpm) – flow velocity: 0.3…10 m/s |
Performance Data |
|
Measurement deviation |
Teach-In: ± 1 % of the measured value (at Teach-In flow rate value) / Standard K-factor: ±2.5% of the measured value |
Linearity |
±0.5% of full scale |
Repeatability | ±0.4% of the measured value |
4…20 mA output uncertainty | ±0.16 mA |
Electrical Data |
|
Operating voltage
|
12…36 V DC ±10%, filtered and regulated Connection to main supply: permanent (through external SELV (Safety Extra Low Volt- age) and LPS (Limited Power Source) power supply) |
Power Source (not supplied) | Limited power source according to UL/EN 60950-1 standards or limited energy circuit according to UL/EN 61010-1 §9.4 |
DC reverse polarity protection | Yes |
Over-voltage protection | Yes |
Current consumption |
< 60 mA (at 12 V DC for current version, without load)
|
Outputs | Transistor: NPN (default setting) or PNP (configurable on request), open collector
Current: according to version, configurable on request
|
Voltage supply cable
|
1.5 mm2 max. cross-section
|
Medium Data |
|
Fluid temperature
|
With fitting in: • PVC: 0…+ 60 °C (+ 32…+ 140 °F) • PP: 0…+ 80 °C (+ 32…+ 176 °F) • Stainless steel or brass: – 15…+ 100 °C (+ 5…+ 212 °F) (if T°ambient ≤ + 45 °C) or -15…+90 °C (+5…+194 °F) (if +45 °C ≤ T°ambient ≤+60 °C) |
Fluid pressure
|
• Max. PN10 (145 PSI) with plastic fitting • Max. PN16 (232 PSI) with metal fitting Detailed information can be found in chapter “5.1. Pressure temperature diagram” on page 8. |
Viscosity
|
Max. 300 cSt
|
Rate of solid particles | Max. 1% . |
Maximum particle size | 0.5 mm |
Process/Port Connection & Communication |
|
Port connection
|
• Metal: Internal or external thread (weld ends, clamp or flange on request) • Plastic: True union with nut and solvent socket, external thread (spigot on request) |
Electrical connection | Free positionable 5 pin M12 male fixed plug or with 1 m cable via cable gland (on request) |
Approvals and Certificates |
|
Standards: Protection class
|
According to IEC/EN 60529: IP67 with device wired and M12 cable plug mounted and tightened / IP65 (with cable gland)
|
CE directives
|
The applied standards, which verify conformity with the EU Directives, can be found on the EU Type Examination Certificate and/or the EU Declaration of conformity (if applicable). |
Pressure equipment directives Certificate | Complying with Article 4, Paragraph 1 of 2014/68/EU directive Detailed information on the pressure equipment directive can be found in chapter “2.1. Pressure Equipment Directive” on page 5. |
Certificate | On request: • Inspection certificate 3.1 (acc. to EN-ISO 10204) • Test report 2.2 (acc. to EN-ISO 10204) • Certification of conformity for the surface quality DIN4762-DIN4768-ISO/4287/1 • 3 points flow calibration certificate • FDA-certificate (only for device with EPDM seal and stainless steel fitting) |
Environment and Installation |
|
Ambient temperature
|
Operation and storage: – 15…+ 60 °C (+ 5…+ 140 °F)
|
Relative air humidity | ≤80%, without condensation |
Height above sea level | Max. 2000 m |
Operating condition |
Continuous
|
Equipment mobility | Fixed |
Application range | Indoor and outdoor (Protect the device against electromagnetic interference, ultraviolet rays and, when installed outdoors, against the effects of climatic conditions) |
Installation category | Category I according to UL/EN 61010-1 |
Pollution degree | Degree 2 according to UL/EN 61010-1 |
*For selecting the correct product please refer to the technical data, images and notes for proper use according to the data sheet, or contact Flu-Tech directly.
สอบถามข้อมูลเพิ่มเติม ติดต่อเรา :
02-384-6060 (อัตโนมัติ) [email protected] บริษัท ฟลูเทค จำกัด Flu-tech @flutech.co.th