Digital electropneumatic process controller for the integrated mounting on process control valves
The compact process controller Type 8693 is optimized for integrated mounting on the pneumatic actuators in the process valve series Type 23xx/2103 and is specially designed for the requirements of a hygienic process environment. The actual value of the process factor is directly supplied to the device as 4…20 mA, PT100 or a frequency signal. The process controller calculates the setpoint for the subordinated positioner through the variance comparison. Due to the analogue feedback all analogue values on the controlling level can be transferred.
DOWNLOAD CATALOG (ดาวน์โหลดแคตตาล็อก)
BURKERT TYPE 8693 สามารถใช้ได้ร่วมกับ
General Technical Data | Burkert - Type 8693
Product features |
|
Dimensions | Detailed information can be found in chapter “3. Dimensions” on page 5 |
Body | PPS, Stainless steel |
Seals | EPDM |
Cover | PC |
Display | Graphic display with backlighting and intuitive menu navigation |
Operating keys | Membrane keypad with 4 keys |
DIP switch | Integrated |
Service-interface | Connection with PC via USB connection |
Configuration tool | PACTware (only for device versions with PROFIBUS, resp. analogue version with serial interface) |
Initialization positioner | Automatic by P.TUNE function (Self-optimization of the PID-Parameter) |
Manual override pilot valve | In manual mode via push-button on control panel |
Display of device and valve status | LEDs (Colours acc. to NAMUR); Only valid for Ethernet and büS versions |
Fieldbus | EtherNet/IP, PROFINET, Modbus TCP, PROFIBUS DP-V1 |
Digital | Bürkert system bus (büS) – based on CANopen |
Position sensor |
|
Measuring principle | Inductive |
Position detection module | Contactless (wear-free) analogue position sensor |
Valve spindle | 3…45 mm |
Electrical data |
|
Operating voltage | 24 V DC ± 25 % UL: NEC Class 2 |
Residual ripple | Max. 10 % |
Protection class | 3 acc. to DIN EN 61140 (VDE 0140 – 1) |
Power consumption | < 5 W |
Input/Output |
|
Digital input | 1 binary input, 0…5 V = log “0”, 10…30 V = log “1” |
Digital output | 2 binary output (optional), galvanically isolated |
Current limitation | 100 mA, output will be synchronised when overloaded |
Analogue output | 1 output (optional) 0/4…20 mA, 0…5/10 V |
Input data setpoint and actual value |
|
Setpoint value setting default | 0/4…20 mA 0…5/10 V |
Input resistance | 0/4…20 mA: 180 Ω 0…5/10 V: 19 kΩ |
Setting 4…20 mA | 180 Ω Input resistance |
Frequency setting | 17 kΩ Input resistance, 0…1000 Hz |
Setting Pt 100 | – 20…+ 220 °C, resolution < 0.1 °C |
Multipole | M12, 8 pin resp. 4- or 5 pin acc. to device version (see “4. Device/Process con-nections” on page 8) |
Cable gland | 2xM16 × 1.5 (cable Ø 5…10 mm) with terminals for cable cross-sections 0.14…1.5 mm² |
*For selecting the correct product please refer to the technical data, images and notes for proper use according to the data sheet, or contact Flu-Tech directly.