Pressure transmitter with IO-Link interface
The pressure transmitter measures and monitors relative and absolute (on request) pressure in liquids and gases. The effect of the pressure on the sensor element generates a signal, which is amplified, digitalized, and processed.
Instead of an analogue output this device offers a digital interface IO-Link. This allows bidirectional data transfer with any IO-Link Master. Data access is done by using the available standardized IODD.
The IO-Link is in accordance to the specification version 1.1. IO-Link. The bidirectional communication is used to read process data, diagnostic information, status messages and to set parameters. The two green LEDs are permanently lit as soon as power is supplied to the device. Once an IO-Link connection is established, the LEDs flash.
The switching behaviour and the switching thresholds of the digital outputs (max. 2 pieces; “PNP” or “NPN”) can be individually configured– as well as many other parameters.
DOWNLOAD CATALOG (ดาวน์โหลดแคตตาล็อก)
General Technical Data
Product Properties |
|
Housing material (non-wetted parts) |
Stainless steel 1.4301 (304)
|
Process connection (wetted parts) |
Stainless steel 1.4404 (316L)
|
Measurement element (wetted parts) | • Membrane in stainless steel 1.4435 (316L) • Welding ring in stainless steel 1.4404 (316L) |
Dimensions
|
Detailed information can be found in chapter “3. Dimensions” on page 7.
|
Measurement technology
|
Metallic thin film strain gauge |
Measured variable | Relative pressure (absolute pressure on request) |
Measuring range | • -0.4…+0.4 bar • -1…+1 bar • -1…+2.5 bar • -1…+5.0 bar • -1…+12.0 bar |
Compensated ambient temperature range (Tamb)
|
– 20…+ 80 °C (- 4…+ 176 °F)
|
Monitoring
|
Measuring circuit: IO-Link event configurable and is available as device status • Process data invalid • Measuring range overflow • Measuring range underflow • Device hardware fault |
Weight |
Approx. 160 g
|
Performance Data |
|
Temperature coefficient (Tc)
|
In compensated T° range
|
Average Tc of zero
|
Version with measuring range: • -0.4…+0.4 bar: 0.020%/°C • -1…+1 bar, -1…+2.5 bar: 0.015%/°C • -1…+5.0 bar, -1…+12.0 bar: 0.010%/°C |
Average Tc of measuring span
|
Version with measuring range -0.4…+0.4 bar, -1…+1 bar, -1…+2.5 bar, -1…+5.0 bar or -1…+12.0 bar: 0.010%/°C |
Thermal hysteresis
|
Version with measuring range: • -0.4…+0.4 bar: 0.15% of measuring span • -1…+1 bar, -1…+2.5 bar, -1…+5.0 bar, -1…+12.0 bar: 0.10%of measuring span |
Zero offset
|
Version with measuring range: • -0.4…0.4 bar: 0.30%of measuring span • -1…+1 bar, -1…+2.5 bar: 0.15%of measuring span • -1…+5.0 bar, -1…+12.0 bar: 0.10%of measuring span |
Response time | • Digital switching output: ≤7 ms • IO-Link: ≤9 ms |
Measuring resolution
|
14 bit
|
Overload limit
|
Version with measuring range: -0.4…+0.4 bar: 1 bar / -1…+1 bar: 4 bar / -1…+2.5 bar: 16 bar / -1…+5.0 bar: 40 bar / -1…+12.0 bar: 100 bar
|
Burst pressure
|
Version with measuring range: • -1…+1 bar: 8 bar • -1…+2.5 bar: 24 bar • -1…+5.0 bar: 60 bar • -1…+12.0 bar: 150 bar • -0.4…+0.4 bar: 1.5 bar |
Measurement deviation
|
• At 20 °C, version with measuring range: – -0.4…+0.4 bar: 0.7% of measuring span – -1…+1bar: 0.6% of measuring span – -1…+2.5 bar : 0.5% of measuring span – -1…+5.0bar: 0.5% of measuring span – -1…+12.0bar: 0.5% of measuring span • At – 20 °C…+ 80°C, version with measuring range: – -0.4…+0.4bar: 2.0% of measuring span – -1…+1bar: 1.8% of measuring span – -1…+2.5bar: 1.3% of measuring span – -1…+5.0bar:1.2% of measuring span – -1…+12.0bar: 1.0% of measuring span |
Hysteresis
|
Version with measuring range -0.4…+0.4 bar, -1…+1 bar, -1…+2.5 bar, -1…+5.0 bar or -1…+12.0 bar: 0.05%of measuring span
|
Linearity
|
• -0.4…+0.4 bar, -1…+1 bar, -1…+2.5 bar or -1…+5.0 bar: 0.3% of measuring span • -1…+12.0 bar: 0.25% of measuring span |
Stability (per year)
|
• -0.4…+0.4 bar: ≤0.3% of measuring span • -1…+1 bar, -1…+2.5 bar, -1…+5.0 bar or -1…+12.0 bar: ≤0.2% of measuring span |
Behaviour of measuring range (IO-Link specification)
|
• Underrange: – linearupto-1.5%ofmeasuringspan – error value: 1 x 1037 • Overrange: – linear up to 5 % of measuring span – error value: 2 x 1037 |
Medium Data |
|
Fluid
|
Liquid and gaseous medium |
Fluid temperature |
– 40…+ 125 °C (- 40…+ 257 °F)
|
Electrical Data |
|
Operating voltage
|
In IO-Link operation: 18…32 V DC, filtered and regulated / In switch operation: 9.6…32 V DC, filtered and regulated / Nominal voltage: 24 V DC |
Power source (not supplied) | The auxiliary energy of the pressure sensor must meet SELV requirements; optionally, an energy-limited current circuit according to section 9.3 of DIN EN 61010-1 and UL 61010-1 can be used. |
Current consumption
|
• In idle operation: ≤10 mA • In IO-Link operation: ≤12 mA • In switch operation: ≤ 250 mA (with two digital outputs) |
DC reverse polarity protection
|
Yes
|
Overvoltage protection | No |
Short circuit protection | Yes (clocked) |
Current limiting | Yes |
Switching current |
≤100 mA per output
|
Voltage drop at switching transistor | ≤ 2 V DC |
Galvanic isolation | To pressure connection available |
Signal processing | Input filter: digital filter, second order / filter time constant can be set |
Quantity output signal
|
• 1 digital output in IO-Link operation • 2 digital outputs for switch operation (SIO mode; SIO = standard IO) |
Switching functions configurable output signal | Hysteresis function (Hysteresis configurable) or window function (fixed setting, symmetrical, ±0.25% of the measuring range) / NC or NO contact / Digital output PNP or NPN / Switch-on/switch-off delay (0…100 s) |
Cable
|
4-wire unshielded cable, max. 20 m
|
*For selecting thecorrect product please refer to the technical data, images and notes for proper use according to the data sheet, or contact Flu-Tech directly.
สอบถามข้อมูลเพิ่มเติม ติดต่อเรา :
02-384-6060 (อัตโนมัติ) [email protected] บริษัท ฟลูเทค จำกัด Flu-tech @flutech.co.th