Flowmeter/Threshold detector with paddle wheel
This flowmeter/threshold detector with display is designed for use in clear, neutral or aggressive liquids. The switching outputs enable the direct switching of valves and the establishment of a simple On/Off control circuit within a monitoring system. The switching points can be configured with the 3 keys directly at the display.
The 8032 measuring device (SE32 transmitter + S030 Inline sensor-fitting) is available with freely configurable switching outputs (transistor or relay) or with 4…20 mA process value output. The transmitter can be fitted to the Inline sensor-fitting via a bayonet fitting without having to open the pipeline.
DOWNLOAD CATALOG (ดาวน์โหลดแคตตาล็อก)
TYPE 8032 สามารถใช้ได้ร่วมกับ
General Technical Data
Product properties |
|
Non wetted parts | |
Housing, cover | PC, glass fibre reinforced |
Front panel foil | Polyester |
Screws | Stainless steel |
Cable glands | PA |
Female cable plug/male fixed plug M12 male fixed plug |
• Body, contact holders and cable gland in PA • Cable gland seal and flat seal in NBR PA or PA and CuZn, nickel-plated |
Wetted parts |
|
Sensor-fitting body, sensor armature | Brass, stainless steel, PVC, PP or PVDF (depending on S030 version) |
Seal | FKM or EPDM (depending on S030 version) |
Axis and bearings | Ceramics (Al2O3) |
Paddle wheel | PVDF |
Dimensions | Detailed information can be found in chapter “4. Dimensions” on page 7 |
Pipe diameter | DN06…DN65. |
Compatibility | Any pipe from DN06…DN65 which are fitted with Bürkert S030 Inline sensor-fitting. For the selection of the nominal diameter of the Inline sensor-fittings, see data sheet Type S030. |
Display | 8-digit LCD with backlighting |
Measuring principle | Paddle wheel |
Measuring range | • Flow rate: 0.5…1000 l/min (0.13…265 gpm) • Flow velocity: 0.3…10 m/s |
Performance data |
|
Measurement deviation | • Teach-In: ± 1 % of the measured value1.) (at Teach-In flow rate value) • Standard K-factor: ± 3 % of the measured value1.) |
Repeatability | ± 0.4 % of the measured value1.) |
Linearity | ± 0.5 % of full scale1.) |
4…20 mA output uncertainty | ± 0.5 % of range |
Operating mode | Threshold: window or hysteresis |
Electrical data |
|
Operating voltage | 12…36 V DC ± 10 %, filtered and regulated Connection to main supply: permanent (through external SELV (Safety Extra Low Volt-age) and LPS (Limited Power Source) power supply) |
Power source (not supplied) | Limited power source according to UL/EN 60950-1 standards or limited energy circuit according to UL/EN 61010-1 §9.4 |
Protection against DC polarity reversal | Yes |
Current consumption | ≤ 80 mA (no load) |
Outputs | • Transistor – NPN and/or PNP, open collector – 700 mA max. (500 mA max. per transistor if both transistor outputs are wired) – 0…300 Hz – operation and thresholds can be parametered – NPN-output: 0.2…36 V DC – PNP-output: power supply – protection against short circuits • Relay (non UL device) – single relay output: 250 V AC/3 A or 30 V DC/3 A, operation and thresholds can be parametered – relay output and 4…20 mA current output: 48 V AC/3 A or 30 V DC/3 A, oper-ation and thresholds can be parametered • Relay (UL device) – 30 V AC/42 Vpeak/3 A or 60 V DC/1 A, operation and thresholds can be param-etered • Process value – 4…20 mA, galvanic insulation – loop impedance max.: 1300 Ω at 36 V DC, 1000 Ω at 30 V DC, 700 Ω at 24 V DC, 450 Ω at 18 V DC, 200 Ω at 12 V DC – response time (10…90 %): 3 s with filter 2 (default setting) |
Voltage supply cable | Max. 100 m length, shielded • For female cable plug (supplied): external diameter of wire: 6…7 mm, cross section of wires: 0.25…1.5 mm² • For 5-pins M12 female plug (not supplied): external diameter of wire: 3…6.5 mm, cross section of wires: max. 0.75 mm² • For 8-pins M12 female plug (not supplied): external diameter of wire: 5.9 mm, cross section of wires: 0.25 mm² |
Medium data |
|
Fluid temperature | With sensor-fitting in: • PVC: 0…+ 50 °C (+ 32…+ 122 °F) • PP: 0…+ 80 °C (+ 32…+ 176 °F) • PVDF, stainless steel or brass: – 15…+ 100 °C (+ 5…+ 212 °F) |
Fluid pressure | • PN10 with plastic sensor-fitting • PN16 (PN40 on request) with metal sensor-fitting Detailed information can be found in the data sheet of the Inline sensor-fittings, see data sheet Type S030 for more information. |
Viscosity | Max. 300 cSt |
Rate of solid particles | Max. 1 % . |
Maximum particle size | 0.5 mm |
Process/Port connection & communication |
|
Port connection | • Metal: Internal or external thread, weld ends, clamp or flange • Plastic: true union with nut and solvent/fusion socket, spigot or external thread See data sheet Type S030 for more information. |
Electrical connections | Cable plug acc. to EN 175301-803, free positionable 5 pin M12 male fixed plug or 8 pin M12 male fixed plug |
Approvals and certificates |
|
Standards Degree of protection2.) accord-ing to IEC/EN 60529 |
IP65 under the following conditions: device wired, cover and lid screwed tight and cable plug or glands mounted and tightened or with blind plug if not used |
CE directives | The applied standards, which verify conformity with the EU Directives, can be found on the EU Type Examination Certificate and/or the EU Declaration of conformity (if applicable). |
Pressure Equipment Directive | Complying with Article 4, Paragraph 1 of 2014/68/EU directive Detailed information on the pressure equipment directive can be found in chapter “3.2. Pressure Equipment Directive” on page 9. |
Certification | UL-Recognized for US and Canada |
Environment and installation |
|
Ambient temperature | – 10…+ 60 °C (+ 14…+ 140 °F) (operation and storage) |
Relative air humidity | ≤ 80 %, without condensation |
Height above sea level | Max. 2000 m |
Operating condition | Continuous |
Equipment mobility | Fixed |
Application range | Indoorandoutdoor(protectthedeviceagainstelectromagneticinterference,ultravioletrays andagainsttheeffectsofclimaticconditions) |
Installation category | Category I according to UL/EN 61010-1 |
Pollution degree | Degree 2 according to UL/EN 61010-1 |
*For selecting thecorrect product please refer to the technical data, images and notes for proper use according to the data sheet, or contact Flu-Tech directly.
สอบถามข้อมูลเพิ่มเติม ติดต่อเรา :
02-384-6060 (อัตโนมัติ) [email protected] บริษัท ฟลูเทค จำกัด Flu-tech @flutech.co.th