โซลินอยด์วาล์ว 4/2 ทาง สำหรับระบบนิวเมติกส์
The Type 5420 is a pilot-controlled 4-way seat valve with servo-diaphragms. A minimum differential pressure of 2.5 bar is needed for switch-over. The valve can be mounted on two channel manifolds with a common pressure supply. Type 5420 can be combined with Type 1087, Type 2518, Type 2000, Type 2511, and Type 2513.
DOWNLOAD CATALOG (ดาวน์โหลดแคตตาล็อก)
TYPE 5420 สามารถใช้ได้ร่วมกับ
General Technical Data
Product Properties |
|
Dimensions
|
Detailed information can be found in chapter “4. Dimensions” on page 5
|
Body material |
Polyamide
|
Seal material | NBR |
Coil material | Polyamide, Epoxy |
Orifice | DN3 |
Performance Data |
|
Air pressure quality
|
ISO 8573-1:2010, class 7.4.4
|
Flow rate (QNn-value air) | 200 l/min (Measured at + 20 °C, 6 bar pressure at valve inlet and 1 bar pressure differ- ence) |
Duty cycle | 100% continuously rated |
Response time | Opening: 30 ms (pressure rise 0…90 %) / Closing: 20 ms (pressure drop 100…10%) |
Electrical Data |
|
Operating voltage
|
Standard version: 24 V DC 24/230 V/50…60 Hz ATEX version: 24/110/230 V UC
|
Power consumption | V DC version: 2 W |
Voltage tolerance | V AC version: 11 VA (inrush), 6 VA (hold) |
Medium Data |
|
Medium
|
Neutral medium, e.g. lubricated or unlubricated compressed air
|
Medium temperature | – 10 °C… + 60 °C |
Medium pressure | 2.5…10 bar (Overpressure to the atmospheric pressure) |
Approvals and Certificates |
|
Protection class
|
IP65 with cable plug |
Type of protection (ATEX and IECEx) – Coil with cable |
EPS 18 ATEX 1232 X / IECEx EPS 18.0110X / II 2G Ex mb IIC T5 Gb / II 2D Ex mb IIIC T95 °C Db
|
Type of protection (ATEX and IECEx) – Coil with junction box |
EPS 18 ATEX 1232 X / IECEx EPS 18.0110X / II 2G Ex eb mb IIC T5 Gb / II 2D Ex mb tb IIIC T95 °C Db
|
Product Connections |
|
Port Connection |
G 1⁄8, tube SL 6/4, sub-base
|
Cable plug Type 2518 |
Cable plug Type 2518 acc. to DIN EN 175301 − 803, Form A (previously DIN 43650, Form A) Detailed information can be found in chapter “Cable plug Type 2518, form A acc. to DIN EN 175301-803” on page 9
|
Environment and Installation |
|
Installation
|
As required, preferably with actuator upright
|
Ambient temperature (max.) | 55 °C |
*For selecting the correct product please refer to the technical data, images and notes for proper use according to the data sheet, or contact Flu-Tech directly.
สอบถามข้อมูลเพิ่มเติม ติดต่อเรา :
02-384-6060 (อัตโนมัติ) [email protected] บริษัท ฟลูเทค จำกัด Flu-tech @flutech.co.th