BURKERT – TYPE 5470 consist of a type 6106 pilot rocker solenoid valve and a pneumatic valve. An armature with a tilting bearing, similar to a rocker, tilts within the body of the pilot valve, and switches the valve. The minimal tilting movement of the rocker is non-wearing, and basic lubrication is unnecessary. The type 5470 R is available as a 3/2 and 4/2-way valve. The valves can be mounted together individually using the module flange. In various applications, they can be used advantageously as valve blocks. Different variants are available for service ports 2 and 4.
DOWNLOAD CATALOG (ดาวน์โหลดแคตตาล็อก)
TYPE 5470 สามารถใช้ได้ร่วมกับ
General Technical Data | Burkert – Type 5470
Product Properties | ||
Materials | ||
Body | Polyamide (PA) | |
Inner valve parts | Ultramid | |
Seal material | NBR | |
Nominal diameter | DN4.0 | |
Performance data | ||
Pressure range | 2…10 bar overpressure with respect to atmospheric pressure | |
QNn value air | 300 l/min Flow rate value for air, measurement at + 20 °C, 6 bar pressure at the valve inlet and 1 bar pressure difference | |
Electrical nominal power | 2…3 W Solenoids with integrated rectifier, LED and varistor (UC variant) solenoids | |
Switching times | AC: Opening: 15 ms, closing: 20 ms DC: Opening: 15 ms, closing: 12 ms Measurement at the valve outlet according to ISO 12238 | |
Electrical data | ||
Operating voltage | 24 V DC / 110…120 V DC / 220…240 V DC For alternating voltage use valves with UC coil | |
Voltage tolerance | ± 10 % | |
Electrical power consumption | Complies with the effective coil power in the ordering table Detailed information can be found in chapter “5. Ordering information” on page 12. | |
Medium data | ||
Operating media | Compressed air, neutral gases (5 µm filtration) | |
Medium temperature | - 10…+ 50 °C | |
Approvals and Certificates | ||
Standard version | PTB 01 ATEX 2175: II 2 G Ex ia IIC T5, T6 Gb | |
Explosion-proof version | IECEx PTB 06.0102: Ex ia IIC T5, T6 Gb | |
Protection class | IP65 with leads or cable plug Type 2516 IP30 with cable plug Type 2505 | |
Product connections | ||
Electrical connection | Connector lugs according to DIN EN 175301 – 803, Form C, for cable plugs Type 1057 and Type 2516; rectangular plug (5.08) Detailed information can be found in chapter “5.4. Ordering table accessories” on page 17. | |
Pressure ports 1 and 3 | Module flange | |
Working ports 2 and 4 (variants) | Sleeve G ⅛ Sleeve NPT ⅛ Hose screw connection SL 6/4 mm Plug-in coupling Ø 6 mm | |
Environment and installation | ||
Ambient temperature | - 10…+ 55 °C | |
Ambient temperature | ||
Installation position | Any, preferably actuator face up |