Type 0201 is a normally-closed direct-acting plunger-type solenoid valve. Direct-acting, Sub-base When energized, the solenoid armatureis drawn in against a spring to open the valve. The solenoid epoxy encapsulation efficiently dissipates the heat generated by the coil.
DOWNLOAD CATALOG (ดาวน์โหลดแคตตาล็อก)
Advantages / Benefits
- Brass Body
- Compact Design
- Normally Closed (NC)
- Short Response Times
Applications
- Vacuum
- Pneumatic control
- Neutral gases and liquids
- Gas control, welding technology
- Shut-off, dosing, filing, and ventilating
- Small scale devices, laboratory, and measuring technology
Technical Data |
|
Circuit Function | A 2/2-Way Valve, Normally Closed (NC) |
Body Material |
Body and seat of brass Stainless steel / Valve internals 1.4105, 1.4571
|
Operating Data (Valve) |
|
NBR |
Neutral fluids, e.g. compressed air, town gas, water, hydraulic oil; -10 to + 90 °C
|
FPM |
Hot air, oxygen, per-solutions, hot oils, oils with additves; -10 to +100 °C
|
Max. ambient temperature
|
55 °C
|
Max. viscosity
|
approx. 21 mm2/s
|
Response times
|
Opening 5 – 18 ms / Closing approx. 8 ms
|
Port connection
|
Sub-base |
Operating Data (Actuator) |
|
Operating voltages
|
AC 24, 230, 240 V/50 Hz / DC 12, 24 V/=
|
Voltage tolerance
|
± 10%
|
Power consumption – AC
|
9 VA (inrush) / 6 VA/4 W (hold) |
Power consumption – DC
|
4 W or 2 W depending on version
|
Duty cycle |
100 % continuously rated, reduced for manifold mounting or use 2 W version
|
Cycling rate |
approx.1000 c.p.m.
|
Classification with plug or cable
|
IP65 |
Installation / Accessories |
|
Installation
|
As required, but preferably with solenoid system upright |
Electrical connection
|
Plug connection without cable plug / moulded-in cable on
request / 2 or 3 moulded-in flying leads on request |
Manifold Mounting
The manifolds for 1 to 6 valves have a common pressure inlet and individual outlet for each valve. Type 201 may also be mounted together with Type 301 valves (circuit function C, de-energized, outlet A exhausted) on the same manifold. The electrical connection can be either to the right or left of the manifold.
Manifolds may be coupled together using special push- fit O-ring connecting nipples for linking the pressure inlets P. Manifolds joined together in this way should be securely mounted.
*For selecting the correct product please refer to the technical data, images and notes for proper use according to the data sheet, or contact Flu-Tech directly.