Positive displacement sensor fitting for continuous flow measurement
This positive displacement sensor fitting is specially designed for flow measurement and/or batch control of highly viscous fluids like glue, honey or oil.
This measuring element must be associated to a transmitter SE30, SE32, SE35 or SE36 with hall sensor principle only, quickly and easily connected together by a Quarter-Turn.
The design of this fitting is based on the oval rotor principle. This has proven to be a reliable and highly accurate volumetric method of measuring flow.
Exceptional repeatability and high accuracy over a wide range of viscosities and flowrates are features of that design. The low pressure drop and high pressure rating make it suitable for both gravity and pump (inline) applications
DOWNLOAD CATALOG (ดาวน์โหลดแคตตาล็อก)
BURKERT TYPE S077 สามารถใช้ได้ร่วมกับ
General Technical Data
Product properties |
|
Materials | Please make sure the device materials are compatible with the fluid you are using. Detailed information can be found in chapter “3.1. Chemical Resistance Chart – Bürkert resistApp” on page 4. |
Wetted parts | |
Body | Aluminium, stainless steel 316L (1.4401) |
Seal | FKM or FEP/PTFE encapsulated |
Oval gears | Stainless steel 316L (1.4401) |
Shaft | Stainless steel 316L (1.4401) |
Dimensions | Detailed information can be found in chapter “4. Dimensions” on page 5. |
Measuring principle | Oval gear |
Compatibility | With transmitter SE30, SE32, SE35, SE36 with Hall sensor principle Detailed information can be found in the respective technical data sheets, see data sheets Type SE30 + S077 , Type SE32 + S077 , Type SE35 + S077 , Type SE36 + S077 for more information. |
Pipe diameter | DN 15…DN 100 |
Measuring range | • Viscosity > 5 mPa.s: 2…1200 l/min (0.53…320 gpm) • Viscosity < 5 mPa.s: 3…616 l/min (0.78…320 gpm) |
Performance data | |
Measurement deviation | • With K-factor determined with a teach-in procedure or with the specific K-factor, engraved on the sensor fitting: ± 0.5 % of the measured value (at Teach-In flow rate value) • With standard K-factor: ± 1 % of the measured value |
Repeatability | ± 0.03 % of the measured value |
Medium data |
|
Fluid temperature | With sensor fitting S077 in: • Aluminium: – 20…+ 80 °C (- 4…+ 176 °F) • Stainless steel: – 20…+ 120 °C (- 4…+ 248 °F) |
Fluid pressure (max.) | With sensor fitting S077 in: • DN 15: 55 bar (798.05 PSI) (threaded process connection) • DN 25: 55 bar (798.05 PSI)1.) • DN 40 or DN 50: 18 bar (261.18 PSI) • DN 80: 12 bar (174.12 PSI) • DN 100: 10 bar (145.1 PSI) |
Viscosity | Max. 1 Pa.s (higher on request) |
Rate of solid particles | 0 % |
Process/Port connection & communication |
|
Process connection | • Thread: ½”; 1″; 1½”; 2″; 3″ (G or NPT) • Flange: – 25; 40; 50; 80 or 100 mm DIN PN 16 flange – 1″; 1½”; 2″; 3″ or 4″ ANSI 150LB flange |
Approvals and certificates |
|
CE directives2.) | The applied standards, which verify conformity with the EU Directives, can be found on the EU Type Examination Certificate and/or the EU Declaration of conformity (if applicable) |
Pressure Equipment Directive | Complying with Article 4, Paragraph 1 of 2014/68/EU directive Detailed information on the pressure equipment directive can be found in chapter “2.1. Pressure Equipment Directive” on page 4. |
Environment and installation |
|
Ambient temperature | Operation and storage: 0…+ 60 °C (+ 32…+ 140 °F) |
*For selecting thecorrect product please refer to the technical data, images and notes for proper use according to the data sheet, or contact Flu-Tech directly.
สอบถามข้อมูลเพิ่มเติม ติดต่อเรา :
02-384-6060 (อัตโนมัติ) [email protected] บริษัท ฟลูเทค จำกัด Flu-tech @flutech.co.th