Liquid Flow Meter (LFM)
Type 8708 is an instrument for liquid flow control in process technology. The actual value supplied by the sensor is transmitted through the digital electronics and over a standard signal output or a fi eld bus interface. In the device two calibration curves can be stored, which the user is able to switch between.
DOWNLOAD CATALOG (ดาวน์โหลดแคตตาล็อก)
TYPE 8708 สามารถใช้ได้ร่วมกับ
General Technical Data
Product Properties |
|
Body material
|
Stainless steel
|
Housing material | PC (Polycarbonate) |
Seal material | FKM, EPDM or FFKM |
Dimensions |
Standard version: 107×115.5×28 (BxHxT)
Sub-base version: 107×115.5×43 (BxHxT) |
Total weight |
Approx. 900 g
|
LED display | Indication for: 1. Power 2. Communication (only in fieldbus version), limit (only in analogue version) 3. Error |
Performance Data |
|
Full scale range (QNom)
|
1.5…36l/h (25…600ml/min) regarding water
|
Measuring range | 01:10 |
Max. operating pressure | Up to max. 10 barg; typical max. 2 barg |
Measuring accuracy |
±1.5% o. R. ±0.5% F. S.
|
Repeatability | ±0.5% F. S. |
Response time (t95%) | <500 ms |
Electrical Data |
|
Operating voltage
|
24 V DC
|
Power consumption | Max. 2.5 W (5 W with fieldbus version) |
Voltage tolerance | ±10% |
Residual ripple |
<2%
|
Electrical connection |
Plug D-Sub 15 pin with PROFIBUS DP: M12 socket, 5 pin with CANopen: M12 plug, 5 pin
|
Medium Data |
|
Operating medium
|
Clean and low viscous liquids
|
Calibration medium |
Water (conversion to operating medium with correction function)
|
Medium temperature |
– 10 °C…+ 40 °C
|
Viscosity (max.) |
0.4 to 4 cSt
|
Process/Port Connection & Communication |
|
Port connection
|
G 1⁄8, NPT 1⁄8, G 1⁄4, NPT 1⁄4, Sub-base |
Digital outputs | One relay-output for 1. Limit (process value close to QNom) Current output: 25 V, 1 A, 25 VA |
Digital inputs | Two 1. Not assigned 2. Not assigned |
Digital (communication) interface | Digital via Fieldbus: • PROFIBUS DP V1 • CANopen |
Analogue interfaces | 4…20 mA, 0…20 mA, 0…10 V or 0…5 V Input impedance >20 kΩ (Voltage) resp. <300 Ω (Current) Max. load: 10 mA (Voltage output); max. load: 600 Ω (Current output) |
Environment and Installation |
|
Ambient temperature
|
0 °C…55 °C
|
Installation position | Horizontal or vertical |
Degree of protection | IP40 |
*For selecting the correct product please refer to the technical data, images and notes for proper use according to the data sheet, or contact Flu-Tech directly.
สอบถามข้อมูลเพิ่มเติม ติดต่อเรา :
02-384-6060 (อัตโนมัติ) [email protected] บริษัท ฟลูเทค จำกัด Flu-tech @flutech.co.th