Liquid Flow Controller (LFC)
Type 8718 is an instrument for liquid flow control in process technology. The measured value provided by the sensor will be compared in the digital control electronics with the predefined set point according to the signal; if a control difference is present, the control value output to the proportional valve will be modified using a PI-control algorithm. In this way, the flow can be maintained at a fixed value or a predefined profile can be followed, regardless of pressure variations or other changes in the system. As a control element, a proportional valve working at low friction guarantees ahigh sensitivity and the good control characteristics of the unit.
DOWNLOAD CATALOG (ดาวน์โหลดแคตตาล็อก)
BURKERT TYPE 8718 สามารถใช้ได้ร่วมกับ
General Technical Data
Product Properties |
|
Body material
|
Stainless steel
|
Housing material | PC (Polycarbonate) |
Seal material | FKM, EPDM or FFKM |
Dimensions | Standard version: 107×115.5×28 (BxHxT) Sub-base version: 107×115.5×43 (BxHxT) |
Total weight |
Approx. 1000 g
|
LED display | Indication for 1) Power; 2) Communication (only in analogue version); 3) Error |
Performance Data |
|
Full scale range (QNom) Measuring range
|
1.5…36l/h (25…600ml/min) regarding water
|
Repeatability | 01:10 |
Max. operating pressure | Up to max. 10 barg; typical max. 2 barg |
Measuring accuracy | ±1.5% o. R. ±0.5% F. S. |
Repeatability | ±0.5% F. S. |
Response time (t95%) | <500 ms |
Electrical Data |
|
Operating voltage
|
24 V DC
|
Power consumption | Max. 7.5 W (10 W with fieldbus version) |
Voltage tolerance |
±10%
|
Residual ripple | <2% |
Electrical connection | Plug Sub-D, 15 pin, Socket M12 (PROFIBUS), 5 pin Plug M12 (CANopen), 5 pin |
Medium Data |
|
Operating medium
|
Clean and low viscous liquids
|
Calibration medium | Water (conversion to operating medium with correction function) |
Medium temperature |
– 10 °C…+ 40 °C
|
Viscosity (max.) |
0.4 to 4 cSt
|
Process/Port Connection & Communication |
|
Port connection
|
G 1⁄8, NPT 1⁄8, G 1⁄4, NPT 1⁄4, Sub-base
|
Calibration medium | One relay-output for: 1. Limit (desired value can not be achieved) Current output: 25 V, 1 A, 25 VA |
Digital inputs | Two: 1. Start Autotune 2. Open valve (for purging) |
Digital (communication) interface
|
Digital via Fieldbus: • PROFIBUS DP V1 • CANopen |
Analogue interfaces | 4…20 mA, 0…20 mA, 0…10 V or 0…5 V Input impedance >20 kΩ (Voltage) resp. <300 Ω (Current) Max. load: 10 mA (Voltage output); max. load: 600 Ω (Current output) |
Environment and Installation |
|
Ambient temperature
|
0 °C…55 °C
|
Installation position |
Horizontal or vertical
|
Degree of protection
|
IP40 |
*For selecting the correct product please refer to the technical data, images and notes for proper use according to the data sheet, or contact Flu-Tech directly.
สอบถามข้อมูลเพิ่มเติม ติดต่อเรา :
02-384-6060 (อัตโนมัติ) [email protected] บริษัท ฟลูเทค จำกัด Flu-tech @flutech.co.th