Showing 2983–2989 of 4553 results

จุดเด่นของ 3573D5212Z

  • Internal monitoring – requires no additional monitoring circuitry
  • Automatic lock-out/inhibit upon detection of a malfunction
  • Default to de-energized position upon fault detection
  • Dedicated reset function
  • No undesired automatic reset upon removal of electrical or pneumatic energy sources
  • Built-in non-clogging silencers

จุดเด่นของ 3573D5215W

  • Internal monitoring – requires no additional monitoring circuitry
  • Automatic lock-out/inhibit upon detection of a malfunction
  • Default to de-energized position upon fault detection
  • Dedicated reset function
  • No undesired automatic reset upon removal of electrical or pneumatic energy sources
  • Built-in non-clogging silencers

จุดเด่นของ 3573D5215Z

  • Internal monitoring – requires no additional monitoring circuitry
  • Automatic lock-out/inhibit upon detection of a malfunction
  • Default to de-energized position upon fault detection
  • Dedicated reset function
  • No undesired automatic reset upon removal of electrical or pneumatic energy sources
  • Built-in non-clogging silencers

จุดเด่นของ 3573D5216W

  • Internal monitoring – requires no additional monitoring circuitry
  • Automatic lock-out/inhibit upon detection of a malfunction
  • Default to de-energized position upon fault detection
  • Dedicated reset function
  • No undesired automatic reset upon removal of electrical or pneumatic energy sources
  • Built-in non-clogging silencers

จุดเด่นของ 3573D5216Z

  • Internal monitoring – requires no additional monitoring circuitry
  • Automatic lock-out/inhibit upon detection of a malfunction
  • Default to de-energized position upon fault detection
  • Dedicated reset function
  • No undesired automatic reset upon removal of electrical or pneumatic energy sources
  • Built-in non-clogging silencers

จุดเด่นของ Dual Block & Stop Valve System รุ่น HDBHDC3BAEXA

  • Stops cylinder motion in the event of loss of electrical power
  • Body Size D03
  • ISO 4401, size 06
  • Nominal flow up to 5 gpm
  • Sandwich style mounting between manifold and directional valve
  • Tamper-evident design
  • These valves are not designed for controlling clutch/brake mechanisms on mechanical power presses

ElectroGuard Safety Isolation Systems

ROSS – ElectroGuard Plus Energy Isolation System

  • Helps reduce workplace injuries resulting from complicated Lockout/Tagout procedures
  • A cost-effective solution to conform with OSHA requirements for control of hazardous energy
  • Simplifies operator Lockout/Tagout procedures to help improve productivity
  • Modular, pre-wired for quick installation
  • Higher cycle life than mechanical disconnects, for reduced downtime