Transmitter for Inline sensor-fitting
DOWNLOAD CATALOG (ดาวน์โหลดแคตตาล็อก)
TYPE se32 สามารถใช้ได้ร่วมกับ
General Technical Data
Product properties |
|
Material | Please make sure the device materials are compatible with the fluid you are using. Detailed information can be found in chapter “3.1. Chemical Resistance Chart – Bürkert resistApp” on page 6. |
Non wetted parts | |
Housing, cover | PC, glass fibre reinforced |
Front panel foil | Polyester |
Screws | Stainless steel |
Female cable plug/male fixed plug | • Body, contact holders and cable gland in PA • Cable gland seal and flat seal in NBR |
M12 male fixed plug | PA or PA and nickel-plated brass (CuZn) |
Quarter turn system | PC |
Wetted parts | |
Sensor-fitting body | Aluminium or stainless steel (316L) |
Seal | FKM or FEP/PTFE encapsulated |
Oval gear | PPS, aluminium or stainless steel (316L) |
Shaft | Stainless steel (316L) |
Dimensions | Detailed information can be found in chapter “4. Dimensions” on page 7. |
Measuring principle | Oval gear |
Compatibility | Any pipe from DN 15…DN 100 which is fitted with Bürkert S077 Inline sensor-fitting. For the selection of the nominal diameter of the Inline sensor-fittings, see data sheet Type S077. |
Display | 8-digit LCD with backlighting |
Pipe diameter | DN 15…DN 100 |
Measuring range | • Viscosity > 5 mPa.s: 2…1200 l/min (0.53…320 gpm) • Viscosity < 5 mPa.s: 3…616 l/min (0.78…320 gpm) |
Performance data |
|
Measurement deviation | • With K-factor determined with a teach-in procedure or with the specific K-factor, engraved on the sensor-fitting: ± 0.5 % of the measured value (at Teach-In flow rate value) • With standard K-factor: ± 1 % of the measured value |
Repeatability | ± 0.03 % of the measured value |
Electrical data |
|
Operating voltage | 12…36 V DC ± 10 %, filtered and regulated Connection to main supply: permanent (through external SELV (Safety Extra Low Voltage) and LPS (Limited Power Source) power supply) |
Power source (not supplied) | Limited power source according to UL/EN 60950-1 standards or limited energy circuit according to UL/EN 61010-1 §9.4 |
Protection against DC polar-ity reversal | Yes |
Current consumption | ≤ 80 mA (no load) |
Outputs | • Transistor – NPN and/or PNP, open collector – 700 mA max. (500 mA max. per transistor if both transistor outputs are wired) – 0…300 Hz – operation and thresholds can be parametered – NPN-output: 0.2…36 V DC – PNP-output: power supply – protection against short circuits • Relay (non UL device) – single relay output: 250 V AC/3 A or 30 V DC/3 A, operation and thresholds can be param-etered – relay output and 4…20 mA current output: 48 V AC/3 A or 30 V DC/3 A, operation and thresholds can be parametered • Relay (UL device) – 30 V AC/42 Vpeak/3 A or 60 V DC/1 A, operation and thresholds can be parametered • Process value – 4…20 mA, galvanic insulation – loop impedance max.: 1300 Ω at 36 V DC, 1000 Ω at 30 V DC, 700 Ω at 24 V DC, 450 Ω at 18 V DC, 200 Ω at 12 V DC – response time (10…90 %): 3 s with filter 2 (default setting) |
Voltage supply cable | • For female cable plug (supplied): external diameter of wire: 6…7 mm, cross section of wires: 0.25…1.5 mm² • For 5-pins M12 female plug (not supplied): external diameter of wire: 3…6.5 mm, cross section of wires: max. 0.75 mm² • For 8-pins M12 female plug (not supplied): external diameter of wire: 5.9 mm, cross section of wires: 0.25 mm² |
Medium data |
|
Fluid temperature | With sensor-fitting S077 in: • Aluminium: – 20…+ 80 °C (- 4…+ 176 °F) • Stainless steel: – 20…+ 120 °C (- 4…+ 248 °F) See data sheet Type S077 for more information. |
Fluid pressure (max.) | • DN 15: 55 bar (798.05 PSI) (threaded process connection) • DN25: 55 bar (798.05 PSI)1.) • DN40 or DN50: 18 bar (261.18 PSI) • DN80: 12 bar (174.12 PSI) • DN100: 10 bar (145.1 PSI) See data sheet Type S077 for more information. |
Viscosity | Max. 1 Pa.s (higher on request) |
Rate of solid particles | 0% |
Process/Port connection & communication |
|
Process connection | • Thread: ½”; 1″; 1½”; 2″; 3″ (G or NPT) • Flange: – 25; 40; 50; 80 or 100 mm DIN PN16 flange – 1″; 1½”; 2″; 3″ or 4″ ANSI 150LB flange |
Electrical connection | Cable plug acc. to EN 175301-803, free positionable 5 pin M12 male fixed plug or 8 pin M12 male fixed plug |
Approvals and Certificates |
|
Standards Degree of protection2.) according to IEC/EN 60529 |
IP65 with device wired and plugs mounted and tightened |
Directives CE directives |
The applied standards, which verify conformity with the EU Directives, can be found on the EU Type Examination Certificate and/or the EU Declaration of conformity (if applicable) |
Pressure equipment directives | Complying with Article 4, Paragraph 1 of 2014/68/EU directive Detailed information on the pressure equipment directive can be found in chapter “2.2. Pressure Equipment Directive” on page 5. |
Certification | UL-Recognized for US and Canada |
Environment and installation |
|
Ambient temperature | Operation and storage: 0…+ 60 °C (+ 32…+ 140 °F) |
Relative air humidity | ≤ 80 %, without condensation |
Height above sea level | Max. 2000 m |
Operating condition | Continuous |
Equipment mobility | Fixed |
Application range | Indoor and outdoor (protect the device against electromagnetic interference, ultraviolet rays and against the effects of climatic conditions) |
Installation category | Category I according to UL/EN 61010-1 |
Pollution degree | Degree 2 according to UL/EN 61010-1 |
*For selecting thecorrect product please refer to the technical data, images and notes for proper use according to the data sheet, or contact Flu-Tech directly.
สอบถามข้อมูลเพิ่มเติม ติดต่อเรา :
02-384-6060 (อัตโนมัติ) [email protected] บริษัท ฟลูเทค จำกัด Flu-tech @flutech.co.th