Turbidity Sensor Cube
This sensor cube measures turbidity according to DIN EN ISO 7027 or EPA method 180.1 and is designed for operation on a fluidic backplane in the device Type 8905 Online Analysis System. The continuous analysis of turbidity in water is an indicator of undesirable, undissolved substances in water. The measurement before and after filter stages can indicate the filter effect and enables, for example, the optimisation of backwashing processes. In the best case, this can lead to water and energy savings. The electrical and fluidic connections are made via the backplane of the system. The sensor cube communicates with the system via the digital büS interface, allowing fully automatic login to the online analysis system. If the sensor is plugged into the system, it automatically logs on to the büS and can be parameterised according to customer requirements.
DOWNLOAD CATALOG (ดาวน์โหลดแคตตาล็อก)
BURKERT TYPE ms05 สามารถใช้ได้ร่วมกับ
General Technical Data
Product properties |
|
Material | Please make sure the device materials are compatible with the fluid you are using. Detailed information can be found in chapter “2.1. Chemical Resistance Chart – Bürkert resistApp” on page 4. |
Housing | PPE + PS |
Lever | Zamak, painted |
Seals | EPDM |
Cuvette | • In glass for version with sensor according to DIN EN ISO 7027 • In PET and glass for version with sensor according to EPA method 180.1 |
Valve | Silicone |
Dimensions | Detailed information can be found in chapter “3. Dimensions” on page 5. |
Turbidity sensor | 90° light scattering, replaceable cuvette1) Sensor according to: • DIN EN ISO 7027: IR-Laser • EPA method 180.1: Tungsten lamp |
Compatibility | With Online Analysis System Type 8905 (the electrical and fluidic contact is made via backplane system.) Detailed information can be found in the data sheet of the online analysis system, see data sheet Type 8905 for more information. |
Measuring range | • 0…40 FNU2) with sensor according to DIN EN ISO 7027 • 0…40 NTU2) with sensor according to EPA method 180.1 |
Maintenance | • 12 months nominal, depending on the water quality. Regular manual or automatic cleaning (with Type MZ20, see data sheet Type MZ20 for more information.) • Exchange of desiccant as required, monitoring of humidity by means of integrated sensor |
Electrical data |
|
Operating voltage | 24 V DC through the backplane of the system Type 8905 via büS |
Power consumption | 0.8 VA |
Medium data | |
Fluid | Water without particles: drinking water, industrial water |
pH value | pH 4…pH 9 |
Sample water | |
Temperature | + 3…+ 40 °C (+ 37…+ 104 °F) |
Pressure | PN3 |
Flow rate | > 6 l/h |
Sample water filter | >100 µm |
Process/Port connection & communication |
|
Process connection | Via pinch valve in the fluidic backplane of the Type 8905 Detailed information can be found in the data sheet of the Online Analysis System, see data sheet Type 8905 for more information. |
Electrical connection | Spring contacts in the fluidic backplane of the Type 8905, which is connected to a büS System Detailed information can be found in the data sheet of the Online Analysis System, see data sheet Type 8905 for more information. |
Data transfer | |
Internal communication | Through büS (Bürkert bus, CAN–Protocol) |
External communication by status LED | According to NAMUR NE 107 |
Approvals and Certificates |
|
Degree of protection according to IEC/EN 60529 | IP65, when plugged in the fluidic backplane IP20, as standalone product |
Directives CE directives | The applied standards, which verify conformity with the EU Directives, can be found on the EU Type Examination Certificate and/or the EU Declaration of conformity (if applica-ble) |
Environment and installation |
|
Ambient temperature Operating | + 3…+ 40 °C (+ 37…+ 104 °F) |
Storage and transports | For empty/purged sensor cube: – 10…+ 60 °C (+ 14…+ 140 °F) |
Relative air humidity | ≤ 90 %, without condensation |
Height above sea level | Max. 2000 m |
Operating condition | Continuous |
Equipment mobility | Fixed |
Application range | Indoor and outdoor (Protect the device against electromagnetic interference, ultraviolet rays and, when installed outdoors, against the effects of climatic conditions) |
Installation category | Category I according to UL/EN 61010-1 |
Pollution degree | Degree 2 according to UL/EN 61010-1 |
*For selecting thecorrect product please refer to the technical data, images and notes for proper use according to the data sheet, or contact Flu-Tech directly.