Flow transmitter/ pulse divider
The electronic module Type 8022 operates either
- as a flow transmitter (only with pulse sensors “Low Power” variant Type 8020, 8030 (SE30+S030), SE30+S077) or
- as a pulse divider (with all sensor variants Type 8020, 8030 (SE30+S030), SE30+S077).
The module operates the output of the sensors, displays the flow value and converts it to the signal output in mA or pulse.
In operation as a flow transmitter, the frequency signal of the sensor is converted in a 4…20 mA signal (2-wire operation).
In operation as a pulse divider, the input frequency is converted into an adjustable output frequency.
The use of the display unit allows the switching between the two modes.
DOWNLOAD CATALOG (ดาวน์โหลดแคตตาล็อก)
TYPE 8002 สามารถใช้ได้ร่วมกับ
General Technical Data
Product properties |
|
Material | |
Housing | PA (Polyamide) |
Cover | PSU (Polysulfone) for version without display PA (Polyamide) and polyester for version with display |
Seal | NBR |
Cover seal | EPDM |
Screws | Steel class 4.8, galvanized with chrome-III thick film passivation |
Dimensions | Detailed information can be found in chapter “3. Dimensions” on page 4 |
Performance data |
|
4…20 mA output uncertainty | ± 240 µA |
RepeatabilityNPN/PNP output uncertainty | ± 1 % of measured value |
Electrical data |
|
Operating voltage | 12…30 V DC ± 10 %, filtered and regulated, SELV (safety extra low voltage) circuit with a non dangerous energy level |
Power source (not supplied) | Limited power source according to UL/EN 60950-1 standards or limited energy circuit according to UL/EN 61010-1 §9.4 |
Frequency input | 1…600 Hz |
Outputs 4…20 mA output (Flow transmitter) |
•Only if connected with sensor Type 8020, 8030 (SE30 + S030), SE30 + S077 “Low Power” version |
NPN/PNP output (Pulse divider) | • Max. loop impedance: 1000 Ω at 30 V DC; 700 Ω at 24 V DC; 100 Ω at 12 V DC • With all versions of sensor Type 8020, 8030 (SE30 + S030), SE30 + S077 • 1…600 Hz, “open collector”, max. 50 mA |
Power consumption | • Flow transmitter (4…20 mA output, 2-wire operation): 0.6 W • Pulse divider (NPN/PNP output, 3-wire operation): 3.2 W with – 0.2 W from the device – 1.5 W max. from the flow sensor1.) – 1.5 W max. from the PNP/NPN output1.) |
Process/Port connection & communication |
|
Electrical connection | Terminal strip 4 pins or male M12 connector |
Approvals and Certificates |
|
Standards Degree of protection according to IEC/EN 60529 |
IP65 when device plugged, housing closed, cover screwed tight and cable gland wired or blanked off, or female connector plugged and tightened |
Directives CE directives |
The applied standards, which verify conformity with the EU Directives, can be found on the EU Type Examination Certificate and/or the EU Declaration of conformity (if applicable). |
Certification | UL-Recognized for US and Canada |
Environment and installation |
|
Ambient temperature | – 10…+ 60 °C |
Relative air humidity | ≤ 80 %, without condensation |
Height above sea level | Max. 2000 m |
Operating condition | Continuous |
Equipment mobility | Fixed |
Application range | Indoor and outdoor (protect the device against electromagnetic interference, ultraviolet rays and against the effects of climatic conditions) |
Installation category | Category I according to UL/EN 61010-1 |
Pollution degree | Degree 2 according to UL/EN 61010-1 |
*For selecting thecorrect product please refer to the technical data, images and notes for proper use according to the data sheet, or contact Flu-Tech directly.
สอบถามข้อมูลเพิ่มเติม ติดต่อเรา :
02-384-6060 (อัตโนมัติ) [email protected] บริษัท ฟลูเทค จำกัด Flu-tech @flutech.co.th