Insertion flowmeter with paddle wheel for continuous flow measurement
Flow Meter แบบ Paddle Wheel รุ่น 8020 จะเป็นรุ่น economy type สามารถใช้งานกับท่อได้ตั้งแต่ขนาด DN06 จนถึง DN400
DOWNLOAD DATA SHEETS
Can be combined with
General Technical Data
Product properties |
|
Materials | Please make sure the device materials are compatible with the fluid you are using. Detailed information can be found in chapter “3.1. Chemical Resistance Chart – Bürkert resistApp” on page 5. |
Non wetted parts | |
Housing | PE |
Union nut | PC |
Screws | Stainless steel |
Female cable plug/male fixed plug | • Body, contact holder and cable gland in PA • Cable gland seal and flat seal in NBR |
Wetted parts | |
Seal | FKM (EPDM option) |
Axis | Ceramics (Al2O3) |
Sensor armature, paddle wheel | PVDF |
Dimensions | Detailed information can be found in chapter “4. Dimensions” on page 6. |
Measuring principle | Paddle wheel |
Compatibility | Any pipe from DN 20…DN 400 which is fitted with Bürkert S020 Insertion fitting. For the selection of the nominal diameter of the Insertion fittings, see data sheet Type S020 . |
Pipe diameter | DN 20.)…DN 400 |
Measuring range | • Flow rate: 0.5…75000 l/min (0.13…19813 gpm) • Flow velocity: 0.3…10 m/s |
Performance data |
|
Measurement deviation | • Teach-In: ± 1 % of the measured value1.) at Teach-In flow rate value • Standard K-factor: ± 2.5 % of the measured value1.) |
Repeatability | ± 0.4 % of the measured value1.) |
Linearity | ± 0.5 % of full scale1.) |
Electrical data |
|
Operating voltage | • Pulse version: 12…36 V DC, filtered and regulated Connection to main supply: permanent (through external SELV (Safety Extra Low Voltage) and LPS (Limited Power Source) power supply • Pulse “Low Power” version: via Bürkert transmitter |
Power source (not supplied) | Limited power source according to UL/EN 60950-1 standards or limited energy circuit according to UL/EN 61010-1 §9.4 |
DC reverse polarity protection | Yes |
Overvoltage protection | Yes |
Current consumption | With sensor • Pulse version: ≤ 50 mA • Pulse “Low Power” version: ≤ 0.8 mA |
Outputs | • Pulse version: – Transistor NPN/PNP, open collector – max. 100 mA – 0…300 Hz – duty cycle (pulse duration/period): ½ • Pulse “Low Power” version: – Transistor NPN, open collector – max. 10 mA – 0…300 Hz – duty cycle (pulse duration/period): ½ |
Voltage supply cable | • Max. 50 m length, shielded • Cross section of wires: 0.25…1.5 mm2 |
Medium data |
|
Fluid temperature | With fitting Type S020 in: • PVC: 0…+ 50 °C (+ 32…+ 122 °F) • PP: 0…+ 80 °C (+ 32…+ 176 °F) • PVDF, stainless steel or brass: – 15…+ 80 °C (+ 5…+ 176 °F) See data sheet Type S020 for more information. |
Fluid pressure | Max. PN 10 Detailed information can be found in chapter “5.1. Pressure temperature diagram” on page 7 or see data sheet Type S020 for more information. |
Viscosity | Max. 300 cSt |
Rate of solid particles | Max. 1 % |
Maximum particle size | 0.5 mm |
Process/Port connection & communication |
|
Process connection | G 2″ for use with Type S020 Insertion fitting See data sheet Type S020 for more information. |
Electrical connection | Female cable plug according to EN 175301-803 |
Approvals and certificates |
|
Standards Degree of protection according to IEC/EN 60529 |
IP65 with cable plug mounted and tightened |
CE directives | The applied standards, which verify conformity with the EU Directives, can be found on the EU Type Examination Certificate and/or the EU Declaration of conformity (if applicable). |
Pressure Equipment Directive | Complying with Article 4, Paragraph 1 of 2014/68/EU directive Detailed information on the pressure equipment directive can be found in chapter “2.1. Pressure Equipment Directive” on page 5. |
Environment and installation |
|
Ambient temperature | Operation and storage: – 15…+ 60 °C (+ 5…+ 140 °F) |
Relative air humidity | ≤ 80 %, without condensation |
Height above sea level | Max. 2000 m |
Operating condition | Continuous |
Equipment mobility | Fixed |
Application range | Indoor and outdoor (protect the device against electromagnetic interference, ultraviolet rays and, when installed outdoors, against the effects of climatic conditions) |
Installation category | Category I according to UL/EN 61010-1 |
Pollution degree | Degree 2 according to UL/EN 61010-1 |
*For selecting thecorrect product please refer to the technical data, images and notes for proper use according to the data sheet, or contact Flu-Tech directly.