Filter Failure Alarm
Also this technology, not relying on particles colliding with the probe, is able to measure a more representative area of the stack and eliminate the need of long sensor probe rods.
Thanks to the digital averaging of readings in combination with the alarm delay feature, by properly setting the delay period, the system will exclude short term signal increases associated with pulse cleaning of filters. This translates into a much lower likelihood of having false alarms.
OPERATIONAL RANGE
- Suitable for a wide range of dust collectors designs and configurations
- Dust level response: <1mg/m3 to 500mg/ m3 (<0.028 mg/ft3 to 14 mg/ft3)
- Flue gas velocity from 4m/sec
- Flue gas temperature up to 240°C (464°F)
- Ambient temperature from -20°C to +50°C (-4°F to +122°F)
- Duct sizes from 0.5m
- Hazardous area ATEX II 3GD
- US-EPA MACT compliant
DOWNLOAD CATALOG (ดาวน์โหลดแคตตาล็อก)
PROCESS AND APPLICATION CONDITIONS
Stack temperature range B | –20 to 240°C (–4 to 465°F) |
SENSOR – KEY DATA | |
Flue gas velocity | 4 m/s |
Dust level response | <1 to 500 mg/m³ (dependent upon application) |
Application conditions | Suitable for measurement in non-condensing šue gases. |
Hazardo us zone classification | ATEX Zones 2 (Gas) and 22 (Dust) |
ENVIRONMENTAL INFORMATION | |
Altitude category | max. 2,000 m (6,500 ft.) |
SENSOR SPECIFICATION | |
FILTER FAILURE ALARM MONITOR | |
Sensor variant | Standard sensor: 0–240°C (up to 465°F) |
Probe rod material | 316 Stainless Steel, PTFE (insulator) |
Weight | 900g (2 lb), excl. rod |
Cable entries | 2× M16 cable glands (one blanked) |
ENCLOSURE | |
Ambient temperature range B | 20 to +50°C (–4 to 130°F) |
Protection rating | IP65 |
Material | Die-cast aluminium LM6M (epoxy coated) |
POWER REQUIREMENTS | |
Power supply voltage | 24 V DC (from the control unit) |