Transmitter for INLINE sensor-fitting
The type SE10 is not available anymore since 1/1/23.
Please contact us for a consultation regarding the most suitable successor article for your requirements.
DOWNLOAD CATALOG (ดาวน์โหลดแคตตาล็อก)
General Technical Data
Product Properties |
|
Material
|
Please make sure the device materials are compatible with the fluid you are using. |
Non wetted parts – Cover material
|
PC, +20% glass fibre reinforced
|
Non wetted parts – Housing material | PC, +20% glass fibre reinforced |
Non wetted parts – Screw material |
Stainless steel
|
Non wetted parts – Setting screw material | Plated brass |
Non wetted parts – Female cable plug/male fixed plug material | Body, contact holders and cable gland in PA / Cable gland seal and flat seal in NBR |
Wetted parts – Sensor holder material |
Brass (CuZn39Pb2), stainless steel 316L (1.4404), PVC, PP, PVDF
|
Wetted parts – Axis material |
Stainless steel 316L
|
Wetted parts – Blade material | PVDF |
Wetted parts – Sensor-fitting body material |
Brass (CuZn39Pb2), stainless steel 316L (1.4404), PVC, PP, PVDF
|
Wetted parts – Seal material | FKM (EPDM on request) |
Compatibility
|
Transmitter (SE10) compatible with Bürkert sensor-fitting (S010)
|
Pipe diameter | DN 15…DN 50 |
Dimensions | Detailed information can be found in chapter “4. Dimensions” on page 5. |
Measuring element |
Blade with magnet, Reed contact
|
Measuring principle | Magnetic by switching the Reed contact |
Switching range | 4.7…75.4 l/min |
Electrical Data |
|
Operating voltage
|
Without
|
Output | Reed contact: potential free, form A, switch off or switch on • switching voltage: 150 V DC/250 V AC max. • switching current: 0.8 A max. • switching power: 50 W max., 50 VA • operating current: 2.5 A |
Recommended connection cable |
0.25…0.5 mm2 cross section; max. 100 m length
|
Medium Data |
|
Fluid temperature
|
With sensor-fitting in: • PVC: 0…+ 50 °C (+ 32…+ 122 °F) • PP, PVDF, stainless steel or brass : 0…+ 55 °C (+ 32…+ 131 °F) |
Fluid pressure | • Max. PN 10 (145 PSI) with plastic sensor-fitting • Max. PN 16 (232 PSI) with metal sensor-fitting Detailed information can be found in chapter “5.1. Pressure temperature diagram” on page 9. |
Viscosity
|
Max. 100 cSt
|
Rate of solid particles | Max. 1% |
Maximum particle size | 0.5 mm |
Flow velocity | Max. 10 m/s |
Process/Port Connection & Communication |
|
Port connection
|
• Metal: Internal or external thread, weld ends, clamp or flange • Plastic: True union with nut and solvent socket, external thread or spigot |
Electrical connection | Cable plug: EN 175301-803 (provided) |
Approvals and Certificates |
|
CE directive
|
The applied standards, which verify conformity with the EU Directives, can be found on the EU Type Examination Certificate and/or the EU Declaration of conformity (if applicable).
|
Pressure equipment directive | Complying with Article 4, Paragraph 1 of 2014/68/EU directive |
Environment and Installation |
|
Ambient temperature
|
Operation and storage: 0…+ 55 °C (+ 32…+ 131 °F)
|
Relative air humidity | ≤80%, without condensation |
Height above sea level | Max. 2000 m |
Operating condition | Continuous |
Equipment mobility | Fixed |
Application range | Indoor and outdoor (protect the device against electromagnetic interference, ultraviolet rays and against the effects of climatic conditions) |
Degree of protection according to IEC/ EN 60529
|
IP65 with device wired and cable plug mounted and tightened
|
Installation category
|
Category I according to UL/EN 61010-1
|
Pollution degree | Degree 2 according to UL/EN 61010-1 |
*For selecting the correct product please refer to the technical data, images and notes for proper use according to the data sheet, or contact Flu-Tech directly.