Chlorine (Cl2 ) or chlorine dioxide (ClO2 ) Sensor Cube
This sensor cube measures the free acting chlorine or chlorine dioxide in the water, depending on the variant. The sensor cube is designed for operation on the fluidic backplane in the device Type 8905 Online Analysis System.
DOWNLOAD CATALOG (ดาวน์โหลดแคตตาล็อก)
BURKERT TYPE ms02 สามารถใช้ได้ร่วมกับ
General Technical Data
Product properties |
|
Material | Please make sure the device materials are compatible with the fluid you are using. Detailed information can be found in chapter “2.1. Chemical Resistance Chart – Bürkert resistApp” on page 4. |
Housing | PPE+PS |
Lever | Zamak, painted |
Seals | EPDM |
Dimensions | Detailed information can be found in chapter “3. Dimensions” on page 5. |
Chlorine/chlorine dioxide sensor | Membrane covered PT-cell, amperiometric 3 electrodes measurement, without electro-lyte |
Temperature sensor | Pt1000 Class B, no contact with the water sample |
Compatibility | With Online Analysis System Type 8905 (the electrical and fluidic contact is made via backplane system.) Detailed information can be found in the data sheet of the online analysis system, see data sheet Type 8905 for more information. |
Measuring range |
|
Chlorine measurement (Cl2) | 0.01…5 ppm |
Chlorine dioxide measurement (ClO2) | 0.005…5 ppm |
Maintenance | 12 months nominal, depending on the water quality |
Performance data |
|
Chlorine measurement (Cl2) | |
Sensitivity | – 11 nA/ppm (at pH 5), – 8 nA/ppm (at pH 7) |
pH compensation | Yes, with MS01 sensor cube Detailed information can be found in the data sheet of the pH sensor cube, see data sheet Type MS01 for more information |
Measuring range resolution | 0.01 ppm |
Measurement deviation | ± 0.03 ppm or ± 5 % of the measured value |
Linearity | ± 0.02 ppm of the measured value |
Repeatability | ± 0.02 ppm of the measured value |
Response time (t90) | < 30 s |
Electrical data |
|
Operating voltage | 24 V DC through the backplane of the system Type 8905 via büS |
Power consumption | 0.8 VA |
Medium data |
|
Fluid | Water without particles: drinking water, industrial water |
pH range | pH 4…pH 9 |
Conductivity | >50 µs/cm |
Sample water | |
Temperature | + 3…+ 40 °C (+ 37…+ 104 °F) |
Pressure | PN3 |
Flow rate | 6 l/h |
Process/Port connection & communication |
|
Process connection | Via pinch valve in the fluidic backplane of the Type 8905 Detailed information can be found in the data sheet of t the Online Analysis System, see data sheet Type 8905 for more information. |
Electrical connection | Spring contacts in the fluidic backplane of the Type 8905, which is connected to a büS System Detailed information can be found in the data sheet of t the Online Analysis System, see data sheet Type 8905 for more information. |
*For selecting thecorrect product please refer to the technical data, images and notes for proper use according to the data sheet, or contact Flu-Tech directly.