Mass Flow Controller (MFC) for the dosing of liquids
The mass flow controller (MFC) / mass flow meter (MFM) Type 8756 is particularly suitable for the very precise measurement or control of small quantities of liquid that also require a medium-separated sensor. The measuring principle of the sensor is based on the Coriolis effect and is completely independent of the medium. Pressure and temperature deviations have no impact on the measuring accuracy.
In addition to the flow rate, the density and temperature of the liquid are measured. The device design enables a stable flow measurement that is immune to external impacts and does not require a zero-point adjustment when the process conditions change. All materials that come into contact with the medium are highly resistant and enable use with a variety of liquids, whether aggressive or neutral media.
Type 8756 is available in the variants MFM, MFC with an interface for a modular actuator, MFC with integrated proportional valve and MFC with integrated micro annular gear pump. The high-precision pump is self-priming and the space in contact with the medium is sealed hermetically. It offers a very large control range and generates extremely low pulsations. This variant is used as a control or dosing system for liquids which have to be conveyed from an unpressurised container.
DOWNLOAD CATALOG (ดาวน์โหลดแคตตาล็อก)
BURKERT TYPE 8756 สามารถใช้ได้ร่วมกับ
General Technical Data
Product Properties |
|
Dimensions
|
Detailed information can be found in chapter “4. Dimensions” on page 5.
|
Material |
Aluminium
|
Housing |
Stainless steel 316L (optionally with inspection certificate 3.1 according to EN 10204)
|
Body (wetted) |
Detailed information can be found in the section actuator.
|
Sensor (wetted) |
Stainless steel 316L
|
Actuator (wetted) |
Detailed information can be found in the section actuator.
|
Seals (wetted) |
FFKM or PCTFE (Sealing materials of the valves can be found in the section actuator), metal possible in the modular version
|
Configuration memory |
Industrial μSIM card for easy device replacement
|
Total mass |
>2 kg
|
LED display |
RGB-LED based on NAMUR NE107
|
Software |
Bürkert Communicator (details see “8.1. Software Bürkert Communicator” on page 11)
|
Performance Data |
|
Maximum flow rate
|
25 kg/h
|
Dosing range |
0.05 g…100 g
|
Valve opening time/dosing time | 0.015 s…7 s |
Dosing precision |
0.3% of the measured value
|
Minimum measurable flow rate | Factory setting: 0.08 kg/h (can be reduced to a minimum of 0.01 kg/h) |
Maximum operating pressure |
16 bar(g) (higher operating pressures on request)
|
Accuracy (temperature) | ±1.0 K (with flow >1.5 kg/h) |
Repeatability (temperature) | ±0.5 K (with flow >1.5 kg/h) |
Leak integrity to the outside |
<10-6 mbar * l/s He (depending on seal material)
|
Actuator |
|
Valve Type 6724 – Smallest dosing amount
|
50 mg
|
Valve Type 6724 – Maximum pressure | 5 bar |
Valve Type 6724 – Viscosity (dynamic) | Up to 40 mPas |
Valve Type 6724 – Wetted parts | EPDM, PEEK |
Valve Type 6724 – Protection class | IP40 |
Valve Type 6013 – Smallest dosing amount
|
50 mg
|
Valve Type 6013 – Maximum pressure | 16 bar (higher pressure on request) |
Valve Type 6013 – Viscosity (dynamic) | Up to 350 mPas (higher viscosity on request) |
Valve Type 6013 – Wetted parts | EPDM, stainless steel 1.4305 / 303; 1.4113 / 434; 1.4310 / 301; 1.4303 / 305L |
Valve Type 6013 – Protection class | IP65 |
Further actuators
|
In the modular version, further actuators can be connected. The internal dosing algorithm is capable of dosing with different actuators. |
Electrical Data |
|
Operating voltage
|
24 V DC |
Voltage tolerance | ±10% |
Power consumption | < 14 W (as MFC with actuator Type 6724 / Type 6013) |
Media Data |
|
Operating medium
|
Any neutral and aggressive liquids (chemical resistance of wetted parts assumed)
|
Calibration medium | Water |
Medium temperature |
0 °C…50 °C (higher on request)
|
Viscosity (dynamic) | 0.3…350 mPas (higher on request) |
Process/Port Connection & Communication |
|
Process connection
|
G 1⁄8, NPT 1⁄8, VCR 1⁄8, VCR 1⁄4, compression fitting (1⁄8, 1⁄4, 4 mm, 6 mm)
|
Electrical connection – CANopen or CANopen-based büS |
1x M12 plug, 5 pin
|
Electrical connection – Industrial Ethernet | Planned, information on request |
Environment and Installation |
|
Ambient temperature
|
0…50 °C (deviating temperature ranges on request)
|
Installation position | Any |
Recommended installation position |
Horizontal upright / Horizontal overhead (for optimal onward transport of trapped gas bubbles in the medium)
|
*For selecting the correct product please refer to the technical data, images and notes for proper use according to the data sheet, or contact Flu-Tech directly.
สอบถามข้อมูลเพิ่มเติม ติดต่อเรา :
02-384-6060 (อัตโนมัติ) [email protected] บริษัท ฟลูเทค จำกัด Flu-tech @flutech.co.th