Flow rate controller for gases
The flow rate controller type 8750 represents a closed flow control loop to measure and control gases using the differential pressure principle. The reliable and robust system consists of an ELEMENT control valve, type 2301, the compact process controller type 8693 put on top of the valve and two pressure transmitters, type 8325. The Bürkert flow rate controller does not need a separate flow meter. The valve seat serves as variable orifice. From the pressure difference across the valve and the given density and temperature a volume flow, referring to the conditions programmed, can be calculated. For that the process controller uses the flow characteristics of the valve and the scales of the pressure transmitters programmed. The volume flow set can then be adjusted by changing the stroke of the control valve. The flow rate controller offers a high repeatability and large measuring range. Beneficial is that the control itself is used for both, controling the flow and measuring over an orifice. With the variable orifice of the control valve the measurement range is increased significantly. Low assembly costs and easy commissioning are further advantages of this unique product.
DOWNLOAD CATALOG (ดาวน์โหลดแคตตาล็อก)
TYPE 8750 สามารถใช้ได้ร่วมกับ
General Technical Data
Product properties | |
Dimensions | Detailed information can be found in chapter “4. Dimensions” on page 6. |
Materials | Detailed information can be found in chapter “2. Materials” on page 4. |
Design | Globe control valve with integrated flow measurement and control |
Nominal diameter | DN 15…DN 100 |
Port connection | Flange according to DIN EN 1092 – 1, ANSI B 16.5 or JIS 10K |
Safety setting in case of power failure | Closed (Control function A) |
Flow direction | Against closing direction (under seat) |
Performance data | |
Operating pressure | Valve: 0 bar(g)…16 bar(g) |
Nominal pressure (max.) | PN 25 (DIN EN 1333), Class 150 (DIN EN 1759) |
Pilot pressure | 5.5…7 bar (actuator M, N, P, see “ELEMENT version, actuator M (70 mm), N (90 mm), P (130 mm)” on page 4) 5…6 bar (actuator L, see “CLASSIC version, actuator L (225 mm)” on page 5) Optional on request: version for reduced control pressure from 3.5 bar |
Seat leakage acc. to DIN EN 60534 – 4 |
Leakage class VI for PTFE (soft sealing) |
KVS values | 2.1 m³/h…140 m³/h, see “5.1. Fluidic data” on page 8 |
Operating characteristic | Linear or equal percentage |
Theoretical range ability | Up to 50:1 |
Flow rate measurement | |
Measured variable | Volume flow, reference conditions programmable |
Measuring principle | Differential pressure via orifice plate and pressure transmitter on the inlet and outlet side of the orifice plate |
Pressure measurement ranges | 0…100 mbar to 0…16 bar |
Pressure measuring principle | Piezoresistive |
Pressure measuring error | ≤ 0.5 % of full scale |
Electrical data | |
Operating voltage | 24 V DC ± 10 % |
Max. residual ripple | 0.1 |
Electrical connection | Operating voltage: circular connector M12x1, 4 pin Analogue input/output signals (for setpoint and actual value): circular connector M12x1, 8 pin Additionally for Bus communication: M12x1, 5 pin Internal signals (for connecting the pressure transmitters): circular connector M8x1, 4 pin |
Communication/signal interface | Analogue (4…20 mA, 0…10 V) or digital (PROFIBUS DP) |
Medium data | |
Medium | Air, oxygen, nitrogen, carbon dioxide, neutral gases, fuel gases |
Medium temperature | – 10…80 °C |
Control medium | Air or neutral gases acc. to DIN ISO 8573 – 1: dust Cl. 7 (< 40 µm), particle density Cl. 5 (< 10 mg/m³), pressure dew point Cl. 3 (≤ 20 °C), oil conc. Cl. X (< 25 mg/m³) |
Process/Port connection & communication | |
Pilot air ports | Threaded connection G ⅛, stainless steel |
Approvals and certificates | |
Approval | Explosion protection: ATEX for zone 3G on request |
Conformity | Materials in contact with medium conform to EG1935/2004 and FDA Oxygen conformity for DN 15 (up to + 60 °C) on request Fuel gases (seals according to EN549) |
Certificate | 2.2 or 3.1 certificate on request |
Environment and installation | |
Ambient temperature | 0…55 °C |
Degree of protection | IP65 / IP67 acc. to EN 60529 |
*For selecting thecorrect product please refer to the technical data, images and notes for proper use according to the data sheet, or contact Flu-Tech directly.
สอบถามข้อมูลเพิ่มเติม ติดต่อเรา :
02-384-6060 (อัตโนมัติ) [email protected] บริษัท ฟลูเทค จำกัด Flu-tech @flutech.co.th