Control head for decentralised automation of ELEMENT process valves
The control head Type 8691 is designed for decentralized automation of ELEMENT Type 21xx pneumatic process valves. The registration of the valve position is done through a contact-free analogue sensor element, which automatically recognises and saves the valve end position through the Teach function during start-up. The integrated pilot valve controls single or double-acting actuators. As an option a communication interface, AS-Interface, IO-Link or büS (based on CANopen) can be chosen.
The design of the control head and the actuator enables an internal control air routing without external tubings. Besides the electrical position feedback, the status of the device is shown directly on the control head itself through coloured powerful LEDs, even in difficult ambient conditions.
The housing is easy to clean and features proven IP protection and chemically resistant materials for use in hygienic processing in food, beverage and pharmaceutical industries. Focused on wash down applications, the IP protection of the housing is supported by a positive pressure inside the control head. Combined with Bürkert ELEMENT actuators, the pneumatic actuating system enables spring chamber aeration that avoids actuator chamber contamination from the environment.
DOWNLOAD DATA SHEETS
Type 8691 data sheet | control head for automation of ELEMENT process valve | DOWNLOAD DATASHEET | |
Type KK01 data sheet | adapterkits for hygienic process valves | DOWNLOAD DATASHEET |
Can be combined with
General Technical Data
Product properties |
|
Profile | S-B.A.E (A/B-Slave, max. 62 slaves/master) certificate no. 77601 acc. to Specification V3.0 Master class: M3, M4 S-B.F.F (standard slave, max. 31 slaves/master) Master class: M0, M1, M2, M3, M4 |
Electrical data |
|
Operating voltage | 26.5…31.6 V DC, UL: NEC Class 2 |
Via Bus cable | Acc. to specification |
Isolation from bus signal | On request |
Protection class | 3 acc. to DIN EN 61140 |
Max. current consumption | 120 mA |
Current consumption in standard operation | 90 mA (acc. to current reduction; valve + 1 end position achieved) |
Device with external power supply | External power supply (The power supply unit must contain one secured disconnection acc. to IEC 364 – 4 – 41 (PELV or SELV)) |
Max. current consumption | 55 mA (acc. to current reduction ≤ 30 mA) |
Max. current consumption from ASI | 55 mA |
Contact rating | ≤ 1 W via AS-Interface |
Watchdog function | Integrated |
Sensor operating voltage | 24 V ± 10 % (via AS-Interface) |
Current carrying capacity | ≤ 50 mA short circuit proof |
Switching level, high | ≥ 10 V |
Input current, high | Limited to 6.5 mA |
Input current, low | ≤ 1.5 mA |
*For selecting thecorrect product please refer to the technical data, images and notes for proper use according to the data sheet, or contact Flu-Tech directly.
สอบถามข้อมูลเพิ่มเติม ติดต่อเรา :
02-384-6060 (อัตโนมัติ) [email protected] บริษัท ฟลูเทค จำกัด Flu-tech @flutech.co.th