Radar level meter for higher pressure ranges
Type 8137 is a non-contact radar level meter for continuous level measurement.
DOWNLOAD CATALOG (ดาวน์โหลดแคตตาล็อก)
BURKERT TYPE 8137 สามารถใช้ได้ร่วมกับ
General Technical Data
Product properties |
|
Materials | Please make sure the device materials are compatible with the fluid you are using. Detailed information can be found in chapter “3.1. Chemical Resistance Chart – Bürkert resistApp” on page 5. |
Non wetted parts | |
Housing | PBT, Stainless steel 316L (1.4404) |
Cover | PC transparent |
Seal between housing and housing cover | EPDM |
Cable gland | PA |
Blind plug | PA |
Ground terminal | Stainless steel 316Ti/316L (1.4571/1.4435) |
Wetted parts | |
Process connection | Stainless steel 316L |
Process seal | NBR with aramid fibres for device with thread process connection (for others versions not included in the delivery) |
Antenna | Stainless steel 316L |
Antenna cone | PTFE (TFM 1600 PTFE) |
Seal | Antenna system: FKM |
Dimensions | Detailed information can be found in chapter “4. Dimensions” on page 6. |
Weights | 2…17.2 kg (depending on process connection and antenna) |
Measuring variable | Distance between the end of the level meter antenna and the product surface. Detailed information can be found in chapters “5.1. Measurement deviation diagram” on page 8 and “6.1. Measuring principle” on page 8. |
Measuring range | • 0.05…15 m (recommended, with antenna Ø 40 mm) • 0.05…35 m (recommended, with antenna Ø 75 mm)• 0.05…15 m (clamp 2″, DN 25 connection or flange DN 50 version) • 0.05…35 m (flange DN 100) |
Beam angle1.) | • 20° with antenna Ø 40 mm • 10° with antenna Ø 75 mm |
Damping (63 % of the input value) | 0…999 s, adjustable |
Step response time2.) | ≤ 3 s |
Product accessories Display | LCD in full dot matrix (optional, must be ordered separately). Detailed information can be found in chapter “7.4. Ordering chart accessories” on page 11. |
Performance data |
|
Measurement deviation | ± 2 mm (measuring distance > 0.5 m) Detailed information can be found in chapter “5.1. Measurement deviation diagram” on page 8. |
Measuring range resolution | 1 mm |
Measuring frequency | K-Band (26 GHz technology) |
Measuring cycle time2.) | Approx. 450 ms |
Temperature drift | • Digital output: ± 3 mm/10 K, max. 10 mm • Current output: < 0.03 %/10K relating to the 16 mA span or ≤ 0.3 % |
Repeatability4.) | ≤ 1 mm |
Vibration resistance | 4 g with 5…200 Hz according to EN 60068-2-6 (vibration at resonance) |
Shock resistance | 100 g, 6 ms according to EN 60068-2-27 (mechanical shock) |
Electrical data |
|
Operating voltage (Un) | • Without display/configuration module: – 9.6…35 V DC – 9.6…30 V DC (Ex ia instrument) • With display/configuration module: – 16…35 V DC – 16…30 V DC (Ex ia instrument) |
Power Source (not supplied) | Limited power source according to UL/EN 60950-1 standards or limited energy circuit according to UL/EN 61010-1 §9.4 |
Starting current | ≤ 3.6 mA; ≤ 10 mA for 5 ms after switching on |
DC reverse polarity protection | Yes |
Output signal | 4…20 mA/HART |
Signal resolution | 0.3 µA |
Range of the output signal | 3.8…20.5 mA/HART (default setting) |
Load resistor | (Un – Umin.)/0.022 A |
Fault signal | Current output: mA value unchanged, 20.5 mA, 22 mA or < 3.6 mA (adjustable) |
Max. output current | 22 mA |
Residual ripple (at DC) | • For 9.6 V < Un < 18 V: ≤ 0.7 Veff (16…400 Hz) • For 18 V < Un < 35 V: ≤ 1.0 Veff (16…400 Hz) |
Voltage supply cable | • Cable diameter: 5…9 mm • Wire cross-section (spring-loaded terminals): – massive wire, stranded wire: 0.2…2.5 mm2 (AWG 24…14) – stranded wire with end sleeve: 0.2…1.5 mm2 (AWG 24…16) |
Media data |
|
Process temperature | – 40 °C…+ 130 °C (- 40 °F…266 °F) |
Process pressure | Vessel pressure: – 1…40 bar (- 100…4000 kPa/- 14.5…580 psi) or according to flange rules |
Dielectric constant (min.) | εr > 1.6 |
Process/Port connection & communication |
|
Process connection | • Thread G 1½” or NPT 1½” • Flange DN 50 or DN 100 DIN 2501, 2″ or 4″ ANSI B16.5 |
Electrical connection | Cable glands M20 x 1.5 |
Approvals and Certificates |
|
Standards Degree of protection according to IEC/EN 60529 |
IP66/IP67 with M20 x 1.5 gland mounted and tightened |
Overvoltage category according to IEC 61010-1 | Category III |
Protection class according to IEC 61010-1 |
Class III |
Directives | |
CE directives | The applied standards, which verify conformity with the EU Directives, can be found on the EU Type Examination Certificate and/or the EU Declaration of conformity (if applicable) |
NAMUR recommendations | NE21- Electromagnetic compatibility of equipment NE43 – Signal level for fault information from measuring transducers NE53 – Compatibility of field devices and display/adjustment components NE107 – Self-monitoring and diagnosis of field devices |
Approvals | |
ATEX | EN 60079-0, EN 60079-11, EN 60079-26 Detailed information can be found in chapter “2.1. ATEX-Certification” on page 5. |
Environment and installation |
|
Ambient temperature | Operation and storage: – 40 °C…+ 80 °C (- 40 °F…+ 176 °F) |
Relative air humidity | 20…85 %, without condensation |
Height above sea level | By default: max. 2000 m With connected overvoltage protection: max. 5000 m |
Pollution degree | Degree 4 (when used with fulfilled housing protection) |
*For selecting thecorrect product please refer to the technical data, images and notes for proper use according to the data sheet, or contact Flu-Tech directly.
สอบถามข้อมูลเพิ่มเติม ติดต่อเรา :
02-384-6060 (อัตโนมัติ) [email protected] บริษัท ฟลูเทค จำกัด Flu-tech @flutech.co.th