Inline flowmeter with paddle wheel, ELEMENT design
The flowmeter Type 8036 is a compact device, specially designed for measur-ing the flow rate in solid-free liquids, in a variety of applications (water, waste water monitoring, chemical processing, etc.).
Type 8036 is available with:
- 2 configurable outputs: one transistor output (NPN) and one 4…20 mA current output (2-wire)
- 3 configurable outputs: two transistor outputs (NPN/PNP) and one 4…20 mA current output (2-wire)
- 4 configurable outputs: two transistor outputs (NPN/PNP) and two 4…20 mA current outputs (3-wire)
Type 8036 converts the measured signal, displays different values in different units (if display/configuration module mounted) and computes the output signals, which are provided via one or two M12 fixed connectors. Thanks to 1 or 2 transistor outputs, the flowmeter can be used to switch a solenoid valve, activate an alarm and, thanks to 1 or 2 current outputs, establish one or two control loops.
DOWNLOAD CATALOG (ดาวน์โหลดแคตตาล็อก)
BURKERT TYPE 8036 สามารถใช้ได้ร่วมกับ
General Technical Data
Product properties |
|
| Non wetted parts | |
| Housing | Stainless steel 1.4404 (316L), PPS |
| cover | Polycarbonate (PC), transparent (opaque on request) |
| Display/configuration module | PC |
| Navigation key | PBT |
| Seals | EPDM, silicone |
| Screws | Stainless steel 1.4401 (316 (A4)) |
| Fixed connector holder | PPS CF30 |
| Fixed connector | Nickel-plated brass (stainless steel on request) |
| Wetted parts | |
| Sensor-fitting body, sensor armature | Brass, stainless steel, PVC, PP or PVDF (depending on S030 version) |
| Seal | FKM or EPDM (depending on S030 version) |
| Axis and bearings | Ceramics (Al2O3) |
| Paddle wheel, holder | PVDF |
| Dimensions | Detailed information can be found in chapter “4. Dimensions” on page 6 |
| Measuring element | Paddle wheel |
| Compatibility | Any pipe from DN 06…DN 65 which is fitted with Bürkert S030 Inline sensor-fitting.For the selection of the nominal diameter of the Inline sensor-fittings, see data sheet Type S030 . |
| Pipe diameter | DN 06…DN 65 |
| Measuring range | • Flow rate: 0.5…1200 l/min (0.13…320 gpm)• Flow velocity: 0.3…10 m/s |
Performance data |
|
| Measurement deviation | Teach-In: ± 1 % of the measured value1.) (at Teach-In flow rate value) Standard K-factor: ± 2.5 % of the measured value1.) |
| Repeatability | ± 0.4 % of the measured value2.) |
| Linearity | ± 0.5 % of full scale2.) |
| 4…20 mA output uncertainty | ± 1 % of range |
Electrical data |
|
| Operating voltage | • 2 or 3 outputs transmitter (2-wire) version: 14…36 V DC, filtered and regulated• 4 outputs transmitter (3-wire) version: 12…36 V DC, filtered and regulatedConnection to main supply: permanent (through external SELV (Safety Extra Low Voltage) and LPS (Limited Power Source) power supply |
| Power source (not supplied) | Limited power source according to UL/EN 60950-1 standards or limited energy circuit according to UL/EN 61010-1 §9.4 |
| DC reverse polarity protection | Yes |
| Over-voltage protection | Yes |
| Current consumption | With sensor• ≤ 1 A (with transistors load)• 2 or 3 outputs transmitter (2-wire) version: ≤ 25 mA (at 14 V DC without transistors load, with current loop)• 4 outputs transmitter (3-wire) version: ≤ 5 mA (at 12 V DC without transistors load, without current loop) |
| Power consumption | Max. 40 W |
| Outputs | |
| Transistor | Protected against overvoltage, polarity reversals and short circuit•1 transistor output (transmitter 2-wire):– NPN, open collector– 1…36 V DC– Max. 700 mA•2 transistor outputs (transmitter 2 or 3-wire):– Adjustable as sourcing or sinking (respectively both as PNP or NPN ), open collector– Max. 700 mA– 0.5 A max. per transistor if the 2 transistor outputs are wired– NPN-output: 1…36 V DC– PNP-output: Power supply |
| Current | 4…20 mA adjustable as sourcing or sinking (in the same mode as transistor):• 1 current output (transmitter 2-wire)Max. loop impedance: 1100 Ω at 36 V DC; 610 Ω at 24 V DC; 180 Ω at 14 V DC• 2 current outputs (transmitter 3-wire)Max. loop impedance: 1100 Ω at 36 V DC; 610 Ω at 24 V DC; 100 Ω at 12 V DC |
| Voltage supply cable | For the female M12 connector and/or the male M12 connector (not supplied, to order separately, see chapter “10.5. Ordering chart accessories” on page 11) use a shielded cable.• Ø 3…6.5 mm• Cross section of wires: max. 0.75 mm² |
Medium data |
|
| Fluid temperature | With sensor-fitting S030 in:• PVC: 0…+ 50 °C (+ 32…+ 122 °F)• PP: 0…+ 80 °C (+ 32…+ 176 °F)• PVDF, stainless steel or brass: – 15…+ 100 °C (+ 5…+ 212 °F) See data sheet Type S030 for more information. |
| Fluid pressure (max.) | With sensor-fitting S030 in:• plastic: PN 10• metal: PN 16 (PN 40 on request)See data sheet Type S030 for more information. |
| Viscosity | Max. 300 cSt |
| Rate of solid particles | Max. 1 % . |
| Maximum particle size | 0.5 mm |
Process/Port connection & communication |
|
| Process connection | With sensor-fitting S030 in:• plastic: true union, spigot or external thread• metal: internal or external thread, weld ends, Clamp or flange See data sheet Type S030 for more information. |
| Electrical connection | • 2 or 3 outputs transmitter (2-wire) version: 1 x 5 pin M12 male fixed connector• 4 outputs transmitter (3-wire) version: 1 x 5 pin M12 male and 1 x 5 pin M12 female fixed con-nectors |
Approvals and certificates |
|
| StandardsDegree of protection2.) | IP65, IP67 (according to IEC/EN 60529), NEMA 4X (according to NEMA250) with device wired and M12 cable plug mounted and tightened and cover fully screwed down |
| CE directives | The applied standards, which verify conformity with the EU Directives, can be found on the EU Type Examination Certificate and/or the EU Declaration of conformity (if applicable) |
| Pressure Equipment Directive | Complying with Article 4, Paragraph 1 of 2014/68/EU directiveDetailed information on the pressure equipment directive can be found in chapter “3.1. Chemical Resistance Chart – Bürkert resistApp” on page 5. |
| Certification | UL-Recognized for US and Canada |
Environment and installation |
|
| Ambient temperature | Operation and storage: – 10…+ 60 °C (+ 14…+ 140 °F) |
| Relative air humidity | ≤ 85 %, without condensation |
| Height above sea level | Max.2000 m |
| Operating condition | Continuous |
| Equipment mobility | Fixed device |
| Application range | Indoorandoutdoor(protectthedeviceagainstelectromagneticinterference,ultravioletrays andagainsttheeffectsofclimaticconditions) |
| Installation category | Category II according to UL/EN 61010-1 |
| Pollution degree | Degree 2 according to UL/EN 61010-1 |
*For selecting thecorrect product please refer to the technical data, images and notes for proper use according to the data sheet, or contact Flu-Tech directly.
สอบถามข้อมูลเพิ่มเติม ติดต่อเรา :
02-384-6060 (อัตโนมัติ) [email protected] บริษัท ฟลูเทค จำกัด Flu-tech @flutech.co.th