Inline flowmeter with paddle wheel, ELEMENT design
The flowmeter Type 8036 is a compact device, specially designed for measur-ing the flow rate in solid-free liquids, in a variety of applications (water, waste water monitoring, chemical processing, etc.).
Type 8036 is available with:
- 2 configurable outputs: one transistor output (NPN) and one 4…20 mA current output (2-wire)
- 3 configurable outputs: two transistor outputs (NPN/PNP) and one 4…20 mA current output (2-wire)
- 4 configurable outputs: two transistor outputs (NPN/PNP) and two 4…20 mA current outputs (3-wire)
Type 8036 converts the measured signal, displays different values in different units (if display/configuration module mounted) and computes the output signals, which are provided via one or two M12 fixed connectors. Thanks to 1 or 2 transistor outputs, the flowmeter can be used to switch a solenoid valve, activate an alarm and, thanks to 1 or 2 current outputs, establish one or two control loops.
DOWNLOAD CATALOG (ดาวน์โหลดแคตตาล็อก)
BURKERT TYPE 8036 สามารถใช้ได้ร่วมกับ
General Technical Data
Product properties |
|
Non wetted parts | |
Housing | Stainless steel 1.4404 (316L), PPS |
cover | Polycarbonate (PC), transparent (opaque on request) |
Display/configuration module | PC |
Navigation key | PBT |
Seals | EPDM, silicone |
Screws | Stainless steel 1.4401 (316 (A4)) |
Fixed connector holder | PPS CF30 |
Fixed connector | Nickel-plated brass (stainless steel on request) |
Wetted parts | |
Sensor-fitting body, sensor armature | Brass, stainless steel, PVC, PP or PVDF (depending on S030 version) |
Seal | FKM or EPDM (depending on S030 version) |
Axis and bearings | Ceramics (Al2O3) |
Paddle wheel, holder | PVDF |
Dimensions | Detailed information can be found in chapter “4. Dimensions” on page 6 |
Measuring element | Paddle wheel |
Compatibility | Any pipe from DN 06…DN 65 which is fitted with Bürkert S030 Inline sensor-fitting.For the selection of the nominal diameter of the Inline sensor-fittings, see data sheet Type S030 . |
Pipe diameter | DN 06…DN 65 |
Measuring range | • Flow rate: 0.5…1200 l/min (0.13…320 gpm)• Flow velocity: 0.3…10 m/s |
Performance data |
|
Measurement deviation | Teach-In: ± 1 % of the measured value1.) (at Teach-In flow rate value) Standard K-factor: ± 2.5 % of the measured value1.) |
Repeatability | ± 0.4 % of the measured value2.) |
Linearity | ± 0.5 % of full scale2.) |
4…20 mA output uncertainty | ± 1 % of range |
Electrical data |
|
Operating voltage | • 2 or 3 outputs transmitter (2-wire) version: 14…36 V DC, filtered and regulated• 4 outputs transmitter (3-wire) version: 12…36 V DC, filtered and regulatedConnection to main supply: permanent (through external SELV (Safety Extra Low Voltage) and LPS (Limited Power Source) power supply |
Power source (not supplied) | Limited power source according to UL/EN 60950-1 standards or limited energy circuit according to UL/EN 61010-1 §9.4 |
DC reverse polarity protection | Yes |
Over-voltage protection | Yes |
Current consumption | With sensor• ≤ 1 A (with transistors load)• 2 or 3 outputs transmitter (2-wire) version: ≤ 25 mA (at 14 V DC without transistors load, with current loop)• 4 outputs transmitter (3-wire) version: ≤ 5 mA (at 12 V DC without transistors load, without current loop) |
Power consumption | Max. 40 W |
Outputs | |
Transistor | Protected against overvoltage, polarity reversals and short circuit•1 transistor output (transmitter 2-wire):– NPN, open collector– 1…36 V DC– Max. 700 mA•2 transistor outputs (transmitter 2 or 3-wire):– Adjustable as sourcing or sinking (respectively both as PNP or NPN ), open collector– Max. 700 mA– 0.5 A max. per transistor if the 2 transistor outputs are wired– NPN-output: 1…36 V DC– PNP-output: Power supply |
Current | 4…20 mA adjustable as sourcing or sinking (in the same mode as transistor):• 1 current output (transmitter 2-wire)Max. loop impedance: 1100 Ω at 36 V DC; 610 Ω at 24 V DC; 180 Ω at 14 V DC• 2 current outputs (transmitter 3-wire)Max. loop impedance: 1100 Ω at 36 V DC; 610 Ω at 24 V DC; 100 Ω at 12 V DC |
Voltage supply cable | For the female M12 connector and/or the male M12 connector (not supplied, to order separately, see chapter “10.5. Ordering chart accessories” on page 11) use a shielded cable.• Ø 3…6.5 mm• Cross section of wires: max. 0.75 mm² |
Medium data |
|
Fluid temperature | With sensor-fitting S030 in:• PVC: 0…+ 50 °C (+ 32…+ 122 °F)• PP: 0…+ 80 °C (+ 32…+ 176 °F)• PVDF, stainless steel or brass: – 15…+ 100 °C (+ 5…+ 212 °F) See data sheet Type S030 for more information. |
Fluid pressure (max.) | With sensor-fitting S030 in:• plastic: PN 10• metal: PN 16 (PN 40 on request)See data sheet Type S030 for more information. |
Viscosity | Max. 300 cSt |
Rate of solid particles | Max. 1 % . |
Maximum particle size | 0.5 mm |
Process/Port connection & communication |
|
Process connection | With sensor-fitting S030 in:• plastic: true union, spigot or external thread• metal: internal or external thread, weld ends, Clamp or flange See data sheet Type S030 for more information. |
Electrical connection | • 2 or 3 outputs transmitter (2-wire) version: 1 x 5 pin M12 male fixed connector• 4 outputs transmitter (3-wire) version: 1 x 5 pin M12 male and 1 x 5 pin M12 female fixed con-nectors |
Approvals and certificates |
|
StandardsDegree of protection2.) | IP65, IP67 (according to IEC/EN 60529), NEMA 4X (according to NEMA250) with device wired and M12 cable plug mounted and tightened and cover fully screwed down |
CE directives | The applied standards, which verify conformity with the EU Directives, can be found on the EU Type Examination Certificate and/or the EU Declaration of conformity (if applicable) |
Pressure Equipment Directive | Complying with Article 4, Paragraph 1 of 2014/68/EU directiveDetailed information on the pressure equipment directive can be found in chapter “3.1. Chemical Resistance Chart – Bürkert resistApp” on page 5. |
Certification | UL-Recognized for US and Canada |
Environment and installation |
|
Ambient temperature | Operation and storage: – 10…+ 60 °C (+ 14…+ 140 °F) |
Relative air humidity | ≤ 85 %, without condensation |
Height above sea level | Max.2000 m |
Operating condition | Continuous |
Equipment mobility | Fixed device |
Application range | Indoorandoutdoor(protectthedeviceagainstelectromagneticinterference,ultravioletrays andagainsttheeffectsofclimaticconditions) |
Installation category | Category II according to UL/EN 61010-1 |
Pollution degree | Degree 2 according to UL/EN 61010-1 |