Insertion flowmeter with paddle wheel for continuous flow measurement
Flow Meter แบบ Paddle Wheel รุ่น 8020 จะเป็นรุ่น economy type สามารถใช้งานกับท่อได้ตั้งแต่ขนาด DN06 จนถึง DN400
DOWNLOAD DATA SHEETS
Type 8020 data sheet | Insertion flowmeter for continuous flow measurement | DOWNLOAD DATASHEET | |
Type S020 data sheet | Insertion fitting for flow or analytical measurement | DOWNLOAD DATASHEET | |
Type 8022 data sheet | Flow transmitter/pulse divider | DOWNLOAD DATASHEET |
Can be combined with
General Technical Data
Product properties |
|
Materials | Please make sure the device materials are compatible with the fluid you are using. Detailed information can be found in chapter “3.1. Chemical Resistance Chart – Bürkert resistApp” on page 5. |
Non wetted parts | |
Housing | PE |
Union nut | PC |
Screws | Stainless steel |
Female cable plug/male fixed plug | • Body, contact holder and cable gland in PA • Cable gland seal and flat seal in NBR |
Wetted parts | |
Seal | FKM (EPDM option) |
Axis | Ceramics (Al2O3) |
Sensor armature, paddle wheel | PVDF |
Dimensions | Detailed information can be found in chapter “4. Dimensions” on page 6. |
Measuring principle | Paddle wheel |
Compatibility | Any pipe from DN 20…DN 400 which is fitted with Bürkert S020 Insertion fitting. For the selection of the nominal diameter of the Insertion fittings, see data sheet Type S020 . |
Pipe diameter | DN 20.)…DN 400 |
Measuring range | • Flow rate: 0.5…75000 l/min (0.13…19813 gpm) • Flow velocity: 0.3…10 m/s |
Performance data |
|
Measurement deviation | • Teach-In: ± 1 % of the measured value1.) at Teach-In flow rate value • Standard K-factor: ± 2.5 % of the measured value1.) |
Repeatability | ± 0.4 % of the measured value1.) |
Linearity | ± 0.5 % of full scale1.) |
Electrical data |
|
Operating voltage | • Pulse version: 12…36 V DC, filtered and regulated Connection to main supply: permanent (through external SELV (Safety Extra Low Voltage) and LPS (Limited Power Source) power supply • Pulse “Low Power” version: via Bürkert transmitter |
Power source (not supplied) | Limited power source according to UL/EN 60950-1 standards or limited energy circuit according to UL/EN 61010-1 §9.4 |
DC reverse polarity protection | Yes |
Overvoltage protection | Yes |
Current consumption | With sensor • Pulse version: ≤ 50 mA • Pulse “Low Power” version: ≤ 0.8 mA |
Outputs | • Pulse version: – Transistor NPN/PNP, open collector – max. 100 mA – 0…300 Hz – duty cycle (pulse duration/period): ½ • Pulse “Low Power” version: – Transistor NPN, open collector – max. 10 mA – 0…300 Hz – duty cycle (pulse duration/period): ½ |
Voltage supply cable | • Max. 50 m length, shielded • Cross section of wires: 0.25…1.5 mm2 |
Medium data |
|
Fluid temperature | With fitting Type S020 in: • PVC: 0…+ 50 °C (+ 32…+ 122 °F) • PP: 0…+ 80 °C (+ 32…+ 176 °F) • PVDF, stainless steel or brass: – 15…+ 80 °C (+ 5…+ 176 °F) See data sheet Type S020 for more information. |
Fluid pressure | Max. PN 10 Detailed information can be found in chapter “5.1. Pressure temperature diagram” on page 7 or see data sheet Type S020 for more information. |
Viscosity | Max. 300 cSt |
Rate of solid particles | Max. 1 % |
Maximum particle size | 0.5 mm |
Process/Port connection & communication |
|
Process connection | G 2″ for use with Type S020 Insertion fitting See data sheet Type S020 for more information. |
Electrical connection | Female cable plug according to EN 175301-803 |
Approvals and certificates |
|
Standards Degree of protection according to IEC/EN 60529 |
IP65 with cable plug mounted and tightened |
CE directives | The applied standards, which verify conformity with the EU Directives, can be found on the EU Type Examination Certificate and/or the EU Declaration of conformity (if applicable). |
Pressure Equipment Directive | Complying with Article 4, Paragraph 1 of 2014/68/EU directive Detailed information on the pressure equipment directive can be found in chapter “2.1. Pressure Equipment Directive” on page 5. |
Environment and installation |
|
Ambient temperature | Operation and storage: – 15…+ 60 °C (+ 5…+ 140 °F) |
Relative air humidity | ≤ 80 %, without condensation |
Height above sea level | Max. 2000 m |
Operating condition | Continuous |
Equipment mobility | Fixed |
Application range | Indoor and outdoor (protect the device against electromagnetic interference, ultraviolet rays and, when installed outdoors, against the effects of climatic conditions) |
Installation category | Category I according to UL/EN 61010-1 |
Pollution degree | Degree 2 according to UL/EN 61010-1 |
*For selecting thecorrect product please refer to the technical data, images and notes for proper use according to the data sheet, or contact Flu-Tech directly.
สอบถามข้อมูลเพิ่มเติม ติดต่อเรา :
02-384-6060 (อัตโนมัติ) [email protected] บริษัท ฟลูเทค จำกัด Flu-tech @flutech.co.th