This flowmeter series is made for the measurement of especially large flow rates and use the calorimetric measuring principle. A heated sensor element is cooled down by the gas flow. This cooling effect which depends on the flow velocity and the gas characteristics serves as a flow indication, the kind of cooling directly depends on the flow velocity and the kind of gas. This kind of mass flow measurement is independent of pressure and temperature. The flowmeter can be used for monitoring air supplies, but also qualifies for the measurement of other gases, see technical data. Type 8007 is available in two versions: – Standard – Heavy Duty (with a robust aluminium die casting electronics housing). In the Heavy Duty version the sensor is encapsulated in stainless steel.
DOWNLOAD CATALOG (ดาวน์โหลดแคตตาล็อก)
TYPE 8007 สามารถใช้ได้ร่วมกับ
General Technical Data
Product Properties |
|
Body material
|
Stainless steel 1.4301 (standard), stainless steel 1.4571 (Heavy Duty) |
Ellectronics housing material |
Polycarbonat (standard), aluminium Die casting (Heavy Duty)
|
Seal material | NBR, FKM (for oxygen) |
Dimensions |
Detailed information can be found in chapter “3. Dimensions” on page 4.
|
Operating pressure | Up to max. 16 bar; optional to PN 40 (standard) Up to max. 50 bar (Heavy Duty) |
Options | Other probe lengths Oxygen conformity declaration Cleaned, free of oil and fat |
Performance Data |
|
Full scale range (QNom)
|
Up to 44030 Nm3/h (air)
|
Pulse output | 1 Impulse per m3 |
Measuring accuracy | ±1.5% o.R. ±0.3% F.S. (o.R.: of reading; F.S.: full scale) (based on air and in consider- ation of the inlet and outlet sections; only when properly installed) |
Measuring range |
01:50
|
Electrical Data |
|
Operating voltage
|
18…36 V DC, 5 W
|
Output signal (Actual value) | 4…20 mA |
Load (current output) | Maximum<500 Ω |
Medium Data |
|
Operating medium
|
Air, nitrogen, oxygen, natural gas, methane, argon |
Temperature of gas |
– 30 °C…+ 110 °C (higher temperatures on request)
|
Calibration medium |
Air, zero point adjustment with operating gas
|
Process/Port Connection & Communication |
|
Digital inputs
|
1 input 10…30 V DC, 2 outputs 24 V DC
|
Digital outputs | RS 485 Interface, Modbus-RTU |
Pulse output | 1 pulse per m3 |
Environment and Installation |
|
Ambient temperature
|
– 30 °C…+ 80 °C (higher temperatures on request)
|
Assembling screw |
G 1⁄2″ (others on request)
|
Degree of protection | IP65 |
*For selecting the correct product please refer to the technical data, images and notes for proper use according to the data sheet, or contact Flu-Tech directly.