Mass Flow Meter (MFM)
The mass flow meter (MFM) type 8006 is suited for measuring the mass f low of high gas flows. The thermal inline sensor is located directly in the gas stream and therefore reaches very fast response times. Type 8006 can optionally be calibrated for two different gases; the user can switch between these two gases. As electrical interfaces both, analog standard signals and f ieldbuses are available. The MFM type 8006 is especially designed for use in harsh environments due to a low sensitivity to contamination and the high protection class.
DOWNLOAD CATALOG (ดาวน์โหลดแคตตาล็อก)
TYPE 8006 สามารถใช้ได้ร่วมกับ
General Technical Data
Product Properties |
|
Body material
|
Stainless steel
|
Housing material | PC (Polycarbonate) |
Seal material | FKM, EPDM or FFKM |
Dimensions |
Standard version: 107×115.5×28 (BxHxT)
Sub-base version: 107×115.5×43 (BxHxT) |
Total weight |
Approx. 900 g
|
LED display | Indication for: 1. Power; 2. Communication (only in fieldbus version), limit (only in analogue version); 3. Error |
Performance Data |
|
Operating pressure (max.)
|
10 bar…25 bar (N2, air, Argon)
|
Response time (t95%) |
<500 ms
|
Nominal flow range (QNom) |
20…2500 lN/min2.), Reference medium N2
|
Measuring accuracy
|
±1.5% o. R.3.) ±0.3% F. S.4.)
|
Repeatability |
±0.1% F. S.
|
Measuring range
|
1:50 (With vertical installation position with flow from top to bottom the measuring range is 1:10)
|
Electrical Data |
|
Standard electrical connection
|
Socket M16, round, 8 pin and socket D-Sub HD15, 15 pin
|
Additionally for PROFIBUS DP electrical connection | M12 socket, 5 pin or D-Sub 9 pin |
Additionally for CANopen electrical connection | Plug M12, 5 pin or D-Sub 9 pin |
RS485 version only electrical connection | Plug D-Sub 9 pin |
Operating voltage |
24 V DC
|
Power consumption (max.)
|
3.5…10 W for fieldbus: 4…12.5 W (depending on version) |
Residual ripple (at DC) | <2% |
Voltage tolerance | ±10% |
Medium Data |
|
Operating medium
|
Neutral, non-contaminated gases, others on request
|
Calibration medium |
Operating gas or air with conversion factor
|
Temperature of gas |
– 10…+ 70 °C (- 10…+ 60 °C for oxygen)
|
Process/Port Connection & Communication |
|
Port connection
|
G 1⁄4, G 3⁄8, G 1⁄2, G 3⁄4, G 1 NPT 1⁄4, NPT 3⁄8, NPT 1⁄2, NPT 3⁄4, NPT 1 With screw-in fitting For more detailed information, please refer to the product enquiry form at the end of the document. |
Output signal (Actual value) analogue communication
|
Analogue signal version: 0…5 V, 0…10 V, 0…20 mA or 4…20 mA Field bus version: None RS485 version (only D-Sub, 9 pin): None |
Max. Current Voltage output analogue communication | Analogue signal version: 10 mA Field bus version: None RS485 version (only D-Sub, 9 pin): None |
Max. Load current output analogue communication | Analogue signal version: 600 Ω Field bus version: None RS485 version (only D-Sub, 9 pin): None |
Fieldbus option: (D-Sub HD15 covered by sealing cap), pins for analogue inputs/out- puts not assigned) | Analogue signal version: None Fieldbus version: PROFIBUS-DP, CANopen RS485 version (only D-Sub, 9 pin): Modbus RTU (via RS interface) |
Digital communication possible via adapter
|
Analogue signal version: RS232 (supports Modbus RTU) RS485, RS422 or USB Fieldbus version: None RS485 version (only D-Sub, 9 pin): RS485, RS422 USB |
Binary inputs (Default, other functions selectable)
|
Analog signal version: Three: 1. not assigned / 2. not assigned/ 3. not assigned Fieldbus version: Three: 1. not assigned / 2. not assigned / 3. not assigned RS485 version (only D-Sub, 9 pin): One: not assigned |
Binary inputs (Default, other functions selectable)
|
Analog signal version: Two relay outputs: 1. Limit (QNom alomost reached) 2. Error (e.g. sensor fault) Load capacity: max. 60 V, 1 A, 60 VA Fieldbus version: Two relay outputs: 1. Limit (QNom alomost reached) 2. Error (e.g. sensor fault) Load capacity: max. 60 V, 1 A, 60 VA RS485 version (only D-Sub, 9 pin): One relay output: 1. Limit (QNom alomost reached) Load capacity: max. 25 V, 1 A, 25 VA |
Environment and Installation |
|
Ambient temperature
|
– 10…+ 45 °C (higher temperatures on request)
|
Installation position | Horizontal or vertical |
Degree of protection | IP65 |
*For selecting the correct product please refer to the technical data, images and notes for proper use according to the data sheet, or contact Flu-Tech directly.
สอบถามข้อมูลเพิ่มเติม ติดต่อเรา :
02-384-6060 (อัตโนมัติ) [email protected] บริษัท ฟลูเทค จำกัด Flu-tech @flutech.co.th