Pneumatic Rocker Solenoid Valve 2/2 or 3/2 way
The direct-acting rocker solenoid valve Burkert type 6106 is designed for use on neutral gaseous mediums. The heat input in the medium is minimal, because the housing is separated from the coil by a stainless steel plate. The valves can be mounted directly or also single or manifold mounted. They are used for dosing, filling, mixing and distributing small quantities of medium.
BURKERT TYPE 6106 สามารถใช้ได้ร่วมกับ
DOWNLOAD CATALOG (ดาวน์โหลดแคตตาล็อก)
General Technical Data | Burkert - Type 6106
Product Properties | ||
Dimensions | Detailed information can be found in chapter “5. Dimensions” on page 6. | |
Material | ||
Seal | FKM | |
Nominal diameter/Orifice | DN 0.9 or DN 1.2 (other orifices on request) | |
Diaphragm | EPDM (AD)1.), PTFE/EPDM (EA)1.), advanced PTFE/EPDM (EU)1.), Gylon®/EPDM laminated (ER)1.) | |
Actuator | PPS, PA | |
Diaphragm size | 8…100; for tube valve body 8…50 mm; for plastic body 15…100 | |
Electrical data | ||
Operating voltage | 12/24 V DC (other voltages on request) | |
Voltage tolerance | ± 10 % | |
Switching frequency | Ca. 16 Hz | |
Standard version | 1 W or 2 W | |
Explosion-proof version | 0.5 W | |
Performance data | ||
Duty cycle | Continuous operation 100 % ED | |
Standard version | Opening: approx. 25 ms (pressure rise 0…10 %) Closing: approx. 25 ms (pressure drop 100 %...90 %) | |
Explosion-proof version | Opening: approx. 25 ms (pressure rise 0…10 %) Closing: approx. 35 ms (pressure drop 100 %...90 %) | |
Medium data | ||
Medium temperature | - 10 °C…+ 55 °C | |
Operating medium | Resistant to neutral gases (5 µm filtering); see chapter “4.1. Chemical Resistance Chart – Bürk-ert resistApp” on page 5. | |
Viscosity (max.) | 21 mm²/s | |
Process/Port connection & communication | ||
Port connection | Bürkert flange CNOMO lateral flange | |
Electrical connection | 2 FEP-flying leads, 0.2 mm², AWG24, length 500 mm Rectangular plug Type 2505 Tag connector sidewards or top, DIN EN 175301 - 803 Form C for cable plug | |
Approvals and Certificates | ||
Standard version | Without | |
Explosion-proof version | PTB 01 ATEX 2175: II 2 G Ex ia IIC T5, T6 Gb IECEx PTB 06.0102: Ex ia IIC T5, T6 Gb | |
Degree of protection | P65 with flying leads or cable plug Type 2516 P30 with rectangular plug Type 2505 | |
Environment and installation | ||
Ambient temperature | - 10 °C…+ 55 °C | |
Installation position | As required, preferably with actuator upright | |
Minimum bending radius for flying leads version | Single bending: 8.5 mm |