Type 0355 – Plunger valve 3/2-way direct-acting
Direct-acting plunger solenoid valve Type 0355 for controlling hot media such as steams, oils and gases.
DOWNLOAD DATA SHEETS
Type 0355 data sheet | plunger-solenoid valve for high temperature | DOWNLOAD DATASHEET |
Can be combined with
General Technical Data
Product Properties |
|
Dimensions |
Detailed information can be found in chapter “4. Dimensions” on page 5.
|
Seal material |
NBR, FKM, PTFE, EPDM
|
Body material | Brass with stainless steel seat 1.4305, stainless steel 1.4581 |
Coil material |
Epoxy
|
Inner part of valve material | Stainless steel |
Nominal diamer |
DN 2.0…DN 4.0
|
Circuit functions |
C (Detailed information can be found in chapter “2. Circuit functions” on page 3)
|
Thermal insulation class of solenoid coil | H |
Performance Data |
|
Duty cycle
|
100% continuous operation
|
Electrical Data |
|
Inrush power consumption
|
AC: 35…40 VA
|
Hold (hot coil) power consumption |
AC: 16 VA/10 W / DC: ca. 12 W
|
High temperature coil CF07 power consumption |
Cold performance: 35 W / Warm performance: 15 W
|
High temperature coil CF09 power consumption | Cold performance: 13 W / Warm performance: 7 W |
Voltage tolerance power consumption |
±10%
|
Medium Data |
|
NBR operating medium |
Neutral fluids, hydraulic oil, oil without additives
|
EPDM operating medium |
Oil and fat-free fluids
|
FKM operating medium |
Per-solutions, hot oils with additives
|
PTFE operating medium |
Steam, organic solvents
|
NBR medium temperature |
– 10 °C…+ 90 °C
|
EPDM medium temperature | – 40 °C…+ 130 °C |
FKM medium temperature | 0 °C…+ 130 °C |
PTFE medium temperature | – 40 °C…+ 180 °C |
Process/Port Connection & Communication |
|
Electrical connection
|
Tag connector acc. to DIN EN 175 301 – 803 Form A for cable plug Type 2508 (supplied as standard)
|
Environment and installation |
|
Installation position | Any, preferably actuator face up |
Ambient temperature
|
Max. + 55 °C (+ 200 °C on request, see “5.3. Ordering chart” on page 7)
|
Approvals and Certificates |
|
Degree of protection
|
IP65 with cable plug / IP50 without cable plug for high temperature devices
|
*For selecting the correct product please refer to the technical data, images and notes for proper use according to the data sheet, or contact Flu-Tech directly.