Direct-acting 2/2 way plunger valve
The direct-acting plunger solenoid valve Type 0255 is also suitable for high pressures and high temperatures.
- Push-over solenoid system
- Compact design, up to DN 6
- high pressures and high temperatures.
- Housing made of brass or stainless steel with threaded connection
DOWNLOAD CATALOG (ดาวน์โหลดแคตตาล็อก)
BURKERT TYPE 0255 สามารถใช้ได้ร่วมกับ
General Technical Data | Burkert - Type 0255
Product Properties Dimensions Detailed information can be found in chapter “4. Dimensions” on page 5. Seal Material FKM, PTFE (others on request) Body Material Brass with stainless steel seat 1.4305 or stainless steel body 1.4581 Coil Material Epoxy Nominal Diameter DN 2.0...DN 6.0 Thermal insulation class of solenoid H Weight 0.6 (brass version) Electrical data Voltage tolerance ±10% Duty cycle 100% continuous operation Medium data Medium temperature with FKM – 10 °C…+ 130 °C Medium temperature with PTFE – 40 °C…+ 180 °C Medium temperature with stainless steel Up to + 250 °C (on request) Operating medium with FKM Hot air, hot oils, oils with additives, per-solutions Operating medium with PTFE Water, steam, fuels, hydraulic materials, alcohol, organic solvents, waste gas Viscosity (max.) Max. 21 mm2/s Process/Port connection & communication Electrical connection Cable plug for Ø 7 mm cable, acc. to DIN EN 175 301 – 803 Form A (supplied as standard) Approvals and certificates Degree of protection IP65 with cable plug, ATEX/IECEx junction box version and cable connection version Environment and installation Installation position As required, preferably with actuator upright Ambient temperature (max.) Max. + 55 °C (+ 250 °C on request, see “6.3. Ordering chart” on page 8)
Product Properties | ||
Dimensions | Detailed information can be found in chapter “4. Dimensions” on page 5. | |
Seal Material | FKM, PTFE (others on request) | |
Body Material | Brass with stainless steel seat 1.4305 or stainless steel body 1.4581 | |
Coil Material | Epoxy | |
Nominal Diameter | DN 2.0...DN 6.0 | |
Thermal insulation class of solenoid | H | |
Weight | 0.6 (brass version) | |
Electrical data | ||
Voltage tolerance | ±10% | |
Duty cycle | 100% continuous operation | |
Medium data | ||
Medium temperature with FKM | – 10 °C…+ 130 °C | |
Medium temperature with PTFE | – 40 °C…+ 180 °C | |
Medium temperature with stainless steel | Up to + 250 °C (on request) | |
Operating medium with FKM | Hot air, hot oils, oils with additives, per-solutions | |
Operating medium with PTFE | Water, steam, fuels, hydraulic materials, alcohol, organic solvents, waste gas | |
Viscosity (max.) | Max. 21 mm2/s | |
Process/Port connection & communication | ||
Electrical connection | Cable plug for Ø 7 mm cable, acc. to DIN EN 175 301 – 803 Form A (supplied as standard) | |
Approvals and certificates | ||
Degree of protection | IP65 with cable plug, ATEX/IECEx junction box version and cable connection version | |
Environment and installation | ||
Installation position | As required, preferably with actuator upright | |
Ambient temperature (max.) | Max. + 55 °C (+ 250 °C on request, see “6.3. Ordering chart” on page 8) |
*For selecting the correct product please refer to the technical data, images and notes for proper use according to the data sheet, or contact Flu-Tech directly.
สอบถามข้อมูลเพิ่มเติม ติดต่อเรา :
02-384-6060 (อัตโนมัติ) [email protected] บริษัท ฟลูเทค จำกัด Flu-tech @flutech.co.th