AIRTEC – Series RE-10 Modular Valve-Terminal for pneumatic control systems
AIRTEC – SERIES RE-10 Manifold system with integrated electrical connection including LED indicators. Each station can accommodate two 3/2-way valves or one 5/2- or 5/3-way valve. All connections are accessible from the front.The valves and the multi-pin plug with cable must be ordered separately.The manifold can be mounted with 4 M5 screws from bottom or from top using the mounting bracket RE-10-B-01 or on a DIN-rail (screws are included).The valve terminal is delivered pre-assembled and function-tested. If not specified with the order, valve configuration is as follows: Valves are mounted according to their order number, starting with high numbers on the side of the multi-pin, ending with low num-bers on the opposite side, followed by blind plates (if ordered).
DOWNLOAD CATALOG (ดาวน์โหลดแคตตาล็อก)
2 x 3/2-way valves
LF-10-310/2-HN-412 2 x 3/2-way, single solenoid, air spring return, NC |
|
LF-10-312/2-HN-412 2 x 3/2-way, single solenoid, air spring return, NO | |
LF-10-314/2-HN-412 2 x 3/2-way, single solenoid, air spring return, 1 x NC, 1 x NO |
5/2-way valves
LF-10-510-HN-412 5/2-way, single solenoid, air spring return | |
LF-10-511-HN-412 5/2-way, single solenoid, mechanical spring return | |
LF-10-520-HN-412 5/2-way, double solenoid |
5/3-way valves
LF-10-530-HN-412 5/3-way, center position closed | |
LF-10-533-HN-412 5/3-way, center position exhausted | |
LF-10-534-HN-412 5/3-way, center position pressurized |
Technical details
Outlets | according to the pneumatical connections of the terminal |
Nominal size | 4 mm |
Temperature range | +5°C ... +50°C |
Medium | Filtered, oil-free and dried compressed air according to ISO 8573-1:2010, Class 7:2:4, instrument air, free of aggressive additives. Alternatively the pressure dew point must be at least 10°C below lowest occurring ambient temperature. |
Materials | Body: Al (anodized), plastic, seals: NBR, FKM, PU inner parts: Al, stainless steel and brass |
Nominal voltage | 24 V DC, ± 10% |
Power consumption | 0.8 W |
Protection | IP 65 according to EN 60529 |
Technical data
Model-no.: | LF-10-310/2-HN-412 | LF-10-312/2-HN-412 | LF-10-314/2-HN-412 |
Operating pressure (bar) | 1.5...8 | 1.5...8 | 1.5...8 |
Pilot pressure (bar) | 1.5...8 | 1.5...8 | 1.5...8 |
Flow rate (Nl/min) | 300 | 220 | 300 / 220 (NC / NO) |
Response time (ms) at 6 bar | on: 14 off: 22 | on: 14 off: 22 | on: 14 off: 22 |
Weight (kg) | 0.050 | 0.050 | 0.050 |
Model-no.: | LF-10-510-HN-412 | LF-10-511-HN-412 | LF-10-520-HN-412 |
Operating pressure (bar) | 1.5...8 | 3...8 | 1.5...8 |
Pilot pressure (bar) | 1.5...8 | 3...8 | 1.5...8 |
Flow rate (Nl/min) | 300 | 300 | 300 |
Response time (ms) at 6 bar | on: 18 off: 28 | on: 14 off: 30 | on: 15 off: 15 |
Weight (kg) | 0.044 | 0.042 | 0.052 |
Model-no.: | LF-10-530-HN-412 | LF-10-533-HN-412 | LF-10-534-HN-412 |
Operating pressure (bar) | 3.5...8 | 3.5...8 | 3.5...8 |
Pilot pressure (bar) | 3.5...8 | 3.5...8 | 3.5...8 |
Flow rate (Nl/min) | 280 | 280 | 300 |
Response time (ms) at 6 bar | on: 20 off: 30 | on: 16 off: 30 | on: 16 off: 30 |
Weight (kg) | 0.050 | 0.050 | 0.050 |