Showing 2458–2464 of 2504 results

  • Compact and lightweight, suitable for OEM use
  • Reverse-flow detection and pulse multiplication functions
  • Ex-protection EExiaIICT6/T4
  • Resistance to high voltage from 50 kV up to 120 kV
  • Special meters with high-pressure connectors for service up to 690 barg (10,000 PSIG)
  • Heated versions are available on request
  • The K-factor (no. of pulses per liter) is nearly constant over a wide range.

  • Superior accuracy – to 0.5% of reading with ±0.03% repeatability
  • Elliptical gear design provides low pressure loss
  • Meter body is available in CS (Std), 304SS or 316SS
  • Bearings are available in CS (Std), 304SS or 316SS as well as Alnico
  • Will accommodate pressures of up to 870 psig (60 bar)
  • Will accommodate viscosities of up to 1000 cP

  • 2 line LCD display with flow rate, totalizer & diagnostics
  • Stores up 512 days of data w/recording interval of 1 to 3600 seconds
  • Velocity range of ±0.98 ft/s~±32 ft/s (±0.1 ~±10 m/s)
  • Pipe sizes from 1-48″ (25~1200) mm
  • Bracket-type transducers for easy installation without mounting belt
  • Data logger includes date, totalizer, signal condition & diagnostic code status
  • Response time of less than 1 second

  • Liners of PE, Peek or Ceramic
  • Fluid velocity range of 0.01m/s – 10m/s, ideal for flow applications
  • ½” NPT or BSP process connections 
  • Ideal for extremely low flow applications
  • Features a built in PT1000 temperature sensor; 0.1°F resolution
  • Available with SS #316L or Hastelloy C electrodes
  • High accuracy – ±0.5% of reading (Velocity > 0.6m/s) or ±3mm/s (Velocity ≤ 0.6m/s)
  • Available with 4-20mA and 0-5KHz pulse and 2A relay outputs
  • RS485 MODBUS; Optional for version w/ display, standard for blind version

จุดเด่นของ SmartMeasurement - ALVT

  • Suitable for a wide variety of applications with steam, gas, and liquid medias
  • No moving parts and no leak paths; no o-ring or graph oil seals to wear, fail or leak
  • Two independent sensors, allowing for better signal amplification and noise reduction
  • Error messages displayed for or erratic flows and flows outside of calibrated ranges
  • Field calibration possible with integral or remote electronics and keypad
  • True 2-wire 4-20 mA interface
  • Wide measuring range, turn-down ratio of 30:1
  • Can measure at Reynolds Numbers ranging from 10,000 to 7,000,000
  • Weatherproof multi-pole connector for power, signal and serial interface
  • Area of measurement can be smaller than pipe connection for better rangeability

จุดเด่นของ SmartMeasurement - ALCM-ST

  • Measurement of mass flow, density, temperature & volume flow
  • Suitable for aggressive & contaminated media
  • Very low pressure drops, only 2″ and 3″ (50mm and 80mm) available
  • Operates at temperatures up to 392°F (200°C)
  • Individual 8-point calibration including NIST-traceable report
  • Optional EX protection

  • High resolution and fast response time; 5 to 50 msec
  • Wide temperature range; -4 ~ 230 °F (-20 ~ 110 °C)
  • Pressures up to 3,600 psig (250 bars) using optional high-pressure flanges
  • Easily cleaned; designed to flush particulates through the meter with the fluid media
  • NPT threaded process connection standard, optional BSP threads & flange connections available
  • Factory calibrated, traceable to NIST
  • Battery-powered display available
  • RS-485 and HART communications available