Showing 2451–2457 of 2504 results

จุดเด่นของ SmartMeasurement - ATMF-IS

  • Direct mass flow measurement of any gas with actual gas calibration
  • Opto-isolated outputs, with graphic display
  • Tracking of overall gas consumption over a turndown ratio of at least 100:1
  • Up to four in-dependent switch able flow curves
  • high contrast photo-emissive OLED display with rate,total, temperature and graphic display
  • Selectable engineering units, dynamically converts the flow rate and total flow
  • Can measure higher velocity than any other thermal mass meter - up to 203 m/s
  • Display calibration milliwatt (mw) for ongoing diagonostics
  • Standard software available multi-curve fit programs
  • Low power dissipation under 2W
  • Low cost SA option for Air, O2 and N2 ONLY (0.3Nm/s~60Nm/s)

จุดเด่นของ SmartMeasurement - ATMFIL

  • Direct mass flow measurement of any gas with actual gas calibration
  • Opto-isolated outputs, with graphic display
  • Tracking of overall gas consumption over a turndown ratio of at least 100:1
  • Up to four independent, switchable flow curves
  • High contrast photo-emissive OLED display with rate, total, temperature and graphic display
  • User-selectable engineering units, dynamically converts the flow rate and total flow
  • Can measure higher velocity than any other thermal mass meter – up to 203 m/s
  • Display calibration milliwatt (mw) for ongoing diagnostics
  • Standard software available multi-curve fit programs
  • Low power dissipation under 2W
  • Flow condioners included with all meters

  • High resolution and fast response time; 5 to 50 msec
  • Wide temperature range; -4 ~ 230 °F (-20 ~ 110 °C)
  • Pressures up to 3,600 psig (250 bars) using optional high-pressure flanges
  • Easily cleaned; designed to flush particulates through the meter with the fluid media
  • NPT threaded process connection standard, optional BSP threads & flange connections available
  • Factory calibrated, traceable to NIST
  • Battery-powered display available
  • RS-485 and HART communicaitons available

จุดเด่นของ SmartMeasurement - ALSONIC-MINI

  • Available in ¼” – 3″ (8-80 mm) pipe sizes
  • Will measure a wide range of fluid velocities; 0.3-16.5 f/s (0.1 ~5.0) m/s
  • Data logger includes daily, monthly and total
  • Outputs include 4-20mA, alarms and MODBUS RTU
  • Suitable pipe materials including stainless steel, carbon steel, copper, PVC, PVDF, polypropylene and HDPE.
  • Accuracy; ±2% of reading
  • Energy and BTU measurement optional
  • NIST traceable calibration certificate

จุดเด่นของ SmartMeasurement - ALVAMT

  • Versatile design may be used for gas, steam, and liquids
  • High resolution and fast response time; – 5 to 50 msec
  • Wide temperature range from -40 up to 750 °F (-40 to 400 °C)
  • High pressure operation up to 6100 psi (420 bar)
  • Process connections including NPT threads, ANSI flanged, & Tri-Clamp available
  • Electronics either intrinsically safe EEx ia II CT5, or Ex proof EEx d II CT6
  • Wide array of materials available including Hastelloy B & C,Ti, Cu, Al, etc..
  • PTFE and other liner materials available
  • NIST-traceable calibration

  • Suitable for aggressive & contaminated media
  • Measurement of mass flow, density, temperature & volume flow
  • High rotation frequency & well-balanced measuring tubes
  • Excellent purging & sterilization capabilities thanks to a construction that is free of dead spots
  • Operates at temps up to 662°F (300°C)
  • Individual 8-point-calibration including report
  • Optional EX protection

จุดเด่นของ SmartMeasurement - ALDPT-MV

  • Multi-parameter capablity in a single transmitter – up to three measured values
  • May be used for level and flow measurement of gas, liquid and steam
  • Modular: interchangeable electronics with self-reconfiguration
  • Advanced diagnostics capabilities
  • Dynamic flow correction with continuous calculation of Reynolds’s number and flow
  • Displays process value(s) and alarm status
  • Mass and standard volume flow in accordance with AGA 3 or DIN EN ISO 5167
  • Convenient; configurable via local operating keypad
  • Linearization of the primary elements
  • Analog 4~20 mA DC two wire linear output
  • HART protocol