Mass Flow Controller for Gases (MFC)
The mass flow controller (MFC) Type 8711 is suited for regulating the mass f low of gases over a big flow range. The thermal MEMS sensor is located directly in the gas stream and therefore reaches very fast response times. A direct-acting proportional valve from Bürkert guarantees a high sensitivity. The integrated PI controller ensures outstanding control characteristics of the MFC. Type 8711 can optionally be calibrated for two different gases; the user can switch between these two gases. As electrical interfaces both, analog standard signals and fieldbuses are available. The mass flow controller type 8711 fits for various applications, like e.g. burner controls, heat treatment, material coatings, bio reactors, fuel cell technology or test benches.
DOWNLOAD CATALOG (ดาวน์โหลดแคตตาล็อก)
TYPE 8711 สามารถใช้ได้ร่วมกับ
General Technical Data
Product properties |
|
Material | |
Basic block | Aluminium or stainless steel |
Body | PC (Polycarbonate) or metal |
Seal | FKM, EPDM |
Dimensions | Detailed information can be found in chapter “3. Dimensions” on page 5. |
Total weight | approx. 500 g (Aluminium) |
LED display | Indication for power, limit (with analogue signals) / communication (with fieldbus) and error |
Performance data |
|
Nominal flow range1.) (QNom) | 10 mlN/min2.)…80 lN/min (N2) Detailed information can be found in chapter “5.2. Flow characteristic” on page 9. |
Measuring range | 1:50, higher measuring range on request |
Max. operating pressure | 10 bar (145 psi) (depending on control valve used) |
Measuring accuracy | ± 0.8 % o. R. ± 0.3 % F. S. (after 1 min. warm up time) |
Repeatability | ± 0.1 % o. R. |
Response time (t95 %) | < 300 ms |
Electrical data |
|
Operating voltage | 24 V DC |
Power consumption | Max. 3.5…14 W (depending on the proportional valve used) |
Voltage tolerance | ± 10 % |
Residual ripple | < 2 % |
Electrical connection | Plug D-Sub, 15 pin with PROFIBUS DP: M12-Socket, 5 pin with CANopen: M12-Plug, 5 pin |
Medium data |
|
Operating medium | Neutral, or aggressive gases |
Calibration medium | Operating gas or air with conversion factor |
Medium temperature | – 10 °C…+ 70 °C (- 10 °C…+ 60 °C for oxygen) |
Process/Port connection & communication |
|
Process connection | NPT ¼, G ¼, screw-in fitting or sub-base, others on request |
Fieldbus option | PROFIBUS-DP, CANopen |
Digital outputs | 1 Relay-output for setpoint not reached Load capacity: 25 V, 1 A, 25 VA |
Digital inputs | Three 1. Start Autotune 2. Not assigned |
Digital (communication) interface | RS232, Modbus RTU (via RS-Adapter), RS485, RS422 or USB (see “6.4. Ordering chart accessories” on page 11) |
Analogue interfaces | 4…20 mA, 0…20 mA, 0…10 V or 0…5 V Input impedance > 20 kΩ (Voltage) resp. < 300 Ω (Current) Max. load: 10 mA (Voltage output); max. load: 600 Ω (Current output) |
Environment and installation |
|
Installation position | Horizontal or vertical |
Degree of protection | IP65 |
Accessories |
|
Software-Tool | Mass Flow Communicator |