Redox Sensor Cube
This sensor cube measures the oxidation reduction potential in the water and is designed for operation on a fluidic backplane in the device key 8905 online analysis system.
The Redox value is one of the most important water parameters. The value is an indicator for the activity of the disinfectant, with no measure of the applied dose but with measure of the remaining residual. T
he electrical and fluidic connections are made via the backplane of the system. The sensor cube communicates with the system via the digital büS interface, allowing fully automatic login to the online analysis system. If the sensor is plugged into the system, it automatically logs on to the büS and can be parameterised according to customer requirements.
The sensor cube is available in 2 variants. The standard version provides protection against biological growth on the reference electrode and is recommended for applications with no or very low chlorine in the water. The drinking water version is without anti-fouling equipment and is mainly required in applications with drinking water approval.
DOWNLOAD CATALOG (ดาวน์โหลดแคตตาล็อก)
BURKERT TYPE ms04 สามารถใช้ได้ร่วมกับ
General Technical Data
Product properties |
|
Materials | Please make sure the device materials are compatible with the fluid you are using. Detailed information can be found in chapter “2.1. Chemical Resistance Chart – Bürkert resistApp” on page 4.A5 |
Housing | PPE+PS |
Lever | Zamak |
Seals | EPDM |
Dimensions | Detailed information can be found in chapter “3. Dimensions” on page 4. |
ORP sensor | Platinum potentiometric 2-electrode measuring cell |
Electrolyte (reference electrode) | • Standard version: Ag/AgCl, 3 mol KCl with biocide for use without chlorine (<0.2 ppm) • Drinking water version: Ag/AgCl, 3 mol KCl without biocide |
Compatibility | With Online Analysis System Type 8905 (the electrical and fluidic contact is made via backplane system.) Detailed information can be found in the data sheet of the online analysis system, see data sheet Type 8905 for more information. |
Measuring range | 2000…+ 2000 mV |
Maintenance | 12 months nominal, depending on the water quality |
Performance data |
|
ORP measurement Measurement deviation | ± 10 mV |
esponse time (t90) | < 10 s |
Medium data |
|
Fluid | Water without particles: drinking water, industrial water |
pH range | pH 4…pH 9 |
Sample water | |
Temperature | + 3…+ 40 °C (+ 37…+ 104 °F) |
Pressure | PN3 |
Flow rate | 6 l/h |
Electrical data |
|
Operating voltage | 24 V DC through the backplane of the system Type 8905 via büS |
Power consumption | 0.8 VA |
Process/Port connection & communication |
|
Process connection | Via pinch valve in the fluidic backplane of the Type 8905 Detailed information can be found in the data sheet of t the Online Analysis System, see data sheet Type 8905 for more information. |
Electrical connection | Spring contacts in the fluidic backplane of the Type 8905, which is connected to a büS System Detailed information can be found in the data sheet of t the Online Analysis System, see data sheet Type 8905 for more information. |
Internal communication | Through büS (Bürkert bus, CANopen protocol) |
External communication by status LED | According to NAMUR NE 107 |
Approvals and Certificates |
|
Standards Degree of protection according to IEC/EN 60529 |
• IP65, when plugged in the fluidic backplane • IP20, as standalone product |
Directives CE directives |
The applied standards, which verify conformity with the EU Directives, can be found on the EU Type Examination Certificate and/or the EU Declaration of conformity (if applica-ble) |
Environment and installation |
|
Ambient temperature Operating | 0…+ 40 °C (+ 32…+ 104 °F) |
Storage and transport | For empty/purged sensor cube • – 10…+ 60 °C (+ 14…+ 140 °F) without the reference electrode • + 3…+ 40 °C (+ 37…+ 104 °F) with the reference electrode |
Relative air humidity | ≤ 90 %, without condensation |
Height above sea level | Max. 2000 m |
Operating condition | Continuous |
Equipment mobility | Fixed |
Application range | Indoor and outdoor (Protect the device against electromagnetic interference, ultraviolet rays and, when installed outdoors, against the effects of climatic conditions) |
Installation category | Category I according to UL/EN 61010-1 |
Pollution degree | Degree 2 according to UL/EN 61010-1 |
*For selecting thecorrect product please refer to the technical data, images and notes for proper use according to the data sheet, or contact Flu-Tech directly.
สอบถามข้อมูลเพิ่มเติม ติดต่อเรา :
02-384-6060 (อัตโนมัติ) [email protected] บริษัท ฟลูเทค จำกัด Flu-tech @flutech.co.th