Mass Flow Meter for Gases (MFM)
The mass flow meter (MFM) type 8702 is suited for measuring the mass flow of gases over a big flow range. The thermal MEMS sensor is located directly in the gas stream and therefore reaches very fast response times. Type 8702 can optionally be calibrated for two different gases; the user can switch between these two gases. As electrical interfaces both, analog standard signals and fieldbuses are available. Type 8712 is especially designed for use in harsh environments due to the high protection class.
DOWNLOAD CATALOG (ดาวน์โหลดแคตตาล็อก)
TYPE 8702 สามารถใช้ได้ร่วมกับ
General Technical Data
Product properties |
|
Materials | |
Block | Stainless steel |
Body | PC (Polycarbonate) |
Seal | FKM, EPDM (others on request) |
Dimensions | Detailed information can be found in chapter “3. Dimensions” on page 4. |
Total weight | 1000 g |
LED display | Indication for power, limit (with analogue signals) / communication (with fieldbus) and error |
Performance data |
|
Nominal flow range (QNom) | 0.01 lN/min2.)…80 lN/min (N2) Detailed information can be found in chapter “6.2. Flow characteristic” on page 8. |
Measuring range | 1:50, higher measuring range on request |
Max. operating pressure | 10 bar (145 psi) (depending on the nominal valve size) |
Measuring accuracy | ± 0.8 % o. R. ± 0.3 % F. S. (after 1 min. warm-up time) |
Repeatability | ± 0.1 % F. S. |
Response time (t95 %) | < 300 ms |
Electrical data |
|
Operating voltage | 24 V DC |
Power consumption | Max. 2.5 W (analog communicator) to 5 W (digital communicator) |
Voltage tolerance | ± 10 % |
Residual ripple | < 2 % |
Electrical connection | Socket M16, round, 8 pin and socket D-Sub HD15, 15 pin with PROFIBUS DP: Socket M12 5 pin (for IP65) or D-Sub 9 pin with CANopen: Plug M12 5 pin (for IP65) or D-Sub 9 pin |
Medium data |
|
Operating medium | Neutral, non-contaminated gases, others on request |
Calibration medium | Operating gas or air with conversion factor |
Medium temperature | – 10 °C…+ 70 °C (- 10 °C…+ 60 °C for oxygen) |
Process/Port connection & communication |
|
Port connection | G ¼, NPT ¼ or screw-in fitting |
Fieldbus option | PROFIBUS-DP, CANopen (D-Sub HD15 covered with sealed plate with fieldbus) |
Digitale Outputs | Two relay outputs 1. Limit (QNom almost reached) 2. Error (i.e. sensor fault) Load capacity: max. 60 V, 1 A, 60 VA |
Digital inputs | Three different functions programmable |
Digital (communication) interface | Digital via RS485 (Half-duplex or full duplex), RS422 |
Analogue interfaces | 4…20 mA, 0…20 mA, 0…10 V or 0…5 V Input impedance > 20 kΩ (Voltage) resp. < 300 Ω (Current) Max. load: 10 mA (Voltage output); max. load: 600 Ω (Current output) |
Environment and installation |
|
Ambient temperature | – 10 °C…+ 50 °C |
Installation | Horizontal or vertical |
Degree of protection | IP65 |
Accessories |
|
Software-Tool | Mass Flow Communicator |