Rotameter (Float-type flow meter)
If a medium with sufficient flow rate flows from bottom to top through a vertically inserted measuring tube, then the floated element is raised so far, and the equilibrium between the lift strength of the medium itself and the weight of the floated element is adjusted. Since the average flow rate is proportional to the flow quantity per time unit, the determined equilibrium corresponds to the flow volume. Flow meters with solenoid floated elements can be equipped with limit value contacts.
DOWNLOAD CATALOG (ดาวน์โหลดแคตตาล็อก)
TYPE TAU003 สามารถใช้ได้ร่วมกับ
General Technical Data
Product properties |
|
Dimensions | More detailed information can be found in the chapter “2. Dimensions” on page 4 |
Materials | |
Measuring tube | PVC-U, Trogamid (PA), Polysulfone (PSU) |
Float | Stainless steel 1.4571, standard for water (without and with solenoid) PP (Polypropylene), standard for air (without |
Inserts | PVDF |
Connection | Standard PVC-U glued socked, metric On request: PVC-U glued socked, ASTM/ANSI PVC-U thread ISO 228/1; RP DIN 2999 PP-H weld socket, DIN 16962 PP welded connection Malleable cast iron thread, ISO 228/1; RP DIN 2999 Stainless steel 1.4571 thread, ISO 228/1; RP DIN 2999 |
Seal (O-ring) | O-ring EPDM, (FPM on request) |
Orifice | DN 10 to DN 65 |
Nominal pressure | Measurement tube made of PVC-U: up to 25 °C max. 10 bar1.); at 60 °C max. 1.5 bar1.) Measurement tube made of Trogamid: up to 50 °C max. 10 bar1.) Measurement tube made of Polysulfone: up to 70 °C max. 10 bar1.); at 100 °C max. 6 bar1.) |
Indicating scale | Absolute in l/h for water 2 adjustable limit indicators |
Option | Control switches, measured value sensor with LED visualization |
Performance data |
|
Measuring range | 3 to 50000 l/h |
Measuring accuracy for overall length up to 200 mm Class 4 acc. to VDE/VDI 3513 sheet 2 | Total error v. measured value: ± 3 %Total error v. final value: ± 1 % |
Measuring accuracy for overall length 350 mm Class 2.5 acc. to VDE/VDI 3513:1:2014 and 3513 – 2:2008 | Total error v. measured value: ± 1.875 %Total error v. final value: ± 0.625 % |
Medium data |
|
Medium | Neutral and aggressive fluids |
Environment and installation |
|
Ambient temperature | Max. + 60 °C |
Installation | Vertical, medium flow from bottom to top |
*For selecting thecorrect product please refer to the technical data, images and notes for proper use according to the data sheet, or contact Flu-Tech directly.
สอบถามข้อมูลเพิ่มเติม ติดต่อเรา :
02-384-6060 (อัตโนมัติ) [email protected] บริษัท ฟลูเทค จำกัด Flu-tech @flutech.co.th