Insertion flowmeter with paddle wheel for continuous flow measurement
Flow Meter แบบ Paddle Wheel รุ่น 8020 จะเป็นรุ่น economy type สามารถใช้งานกับท่อได้ตั้งแต่ขนาด DN06 จนถึง DN400
General Technical Data
Product properties |
|
| Materials | Please make sure the device materials are compatible with the fluid you are using. Detailed information can be found in chapter “3.1. Chemical Resistance Chart – Bürkert resistApp” on page 5. |
| Non wetted parts | |
| Housing | PE |
| Union nut | PC |
| Screws | Stainless steel |
| Female cable plug/male fixed plug | • Body, contact holder and cable gland in PA • Cable gland seal and flat seal in NBR |
| Wetted parts | |
| Seal | FKM (EPDM option) |
| Axis | Ceramics (Al2O3) |
| Sensor armature, paddle wheel | PVDF |
| Dimensions | Detailed information can be found in chapter “4. Dimensions” on page 6. |
| Measuring principle | Paddle wheel |
| Compatibility | Any pipe from DN 20…DN 400 which is fitted with Bürkert S020 Insertion fitting. For the selection of the nominal diameter of the Insertion fittings, see data sheet Type S020 . |
| Pipe diameter | DN 20.)…DN 400 |
| Measuring range | • Flow rate: 0.5…75000 l/min (0.13…19813 gpm) • Flow velocity: 0.3…10 m/s |
Performance data |
|
| Measurement deviation | • Teach-In: ± 1 % of the measured value1.) at Teach-In flow rate value • Standard K-factor: ± 2.5 % of the measured value1.) |
| Repeatability | ± 0.4 % of the measured value1.) |
| Linearity | ± 0.5 % of full scale1.) |
Electrical data |
|
| Operating voltage | • Pulse version: 12…36 V DC, filtered and regulated Connection to main supply: permanent (through external SELV (Safety Extra Low Voltage) and LPS (Limited Power Source) power supply • Pulse “Low Power” version: via Bürkert transmitter |
| Power source (not supplied) | Limited power source according to UL/EN 60950-1 standards or limited energy circuit according to UL/EN 61010-1 §9.4 |
| DC reverse polarity protection | Yes |
| Overvoltage protection | Yes |
| Current consumption | With sensor • Pulse version: ≤ 50 mA • Pulse “Low Power” version: ≤ 0.8 mA |
| Outputs | • Pulse version: – Transistor NPN/PNP, open collector – max. 100 mA – 0…300 Hz – duty cycle (pulse duration/period): ½ • Pulse “Low Power” version: – Transistor NPN, open collector – max. 10 mA – 0…300 Hz – duty cycle (pulse duration/period): ½ |
| Voltage supply cable | • Max. 50 m length, shielded • Cross section of wires: 0.25…1.5 mm2 |
Medium data |
|
| Fluid temperature | With fitting Type S020 in: • PVC: 0…+ 50 °C (+ 32…+ 122 °F) • PP: 0…+ 80 °C (+ 32…+ 176 °F) • PVDF, stainless steel or brass: – 15…+ 80 °C (+ 5…+ 176 °F) See data sheet Type S020 for more information. |
| Fluid pressure | Max. PN 10 Detailed information can be found in chapter “5.1. Pressure temperature diagram” on page 7 or see data sheet Type S020 for more information. |
| Viscosity | Max. 300 cSt |
| Rate of solid particles | Max. 1 % |
| Maximum particle size | 0.5 mm |
Process/Port connection & communication |
|
| Process connection | G 2″ for use with Type S020 Insertion fitting See data sheet Type S020 for more information. |
| Electrical connection | Female cable plug according to EN 175301-803 |
Approvals and certificates |
|
| Standards Degree of protection according to IEC/EN 60529 |
IP65 with cable plug mounted and tightened |
| CE directives | The applied standards, which verify conformity with the EU Directives, can be found on the EU Type Examination Certificate and/or the EU Declaration of conformity (if applicable). |
| Pressure Equipment Directive | Complying with Article 4, Paragraph 1 of 2014/68/EU directive Detailed information on the pressure equipment directive can be found in chapter “2.1. Pressure Equipment Directive” on page 5. |
Environment and installation |
|
| Ambient temperature | Operation and storage: – 15…+ 60 °C (+ 5…+ 140 °F) |
| Relative air humidity | ≤ 80 %, without condensation |
| Height above sea level | Max. 2000 m |
| Operating condition | Continuous |
| Equipment mobility | Fixed |
| Application range | Indoor and outdoor (protect the device against electromagnetic interference, ultraviolet rays and, when installed outdoors, against the effects of climatic conditions) |
| Installation category | Category I according to UL/EN 61010-1 |
| Pollution degree | Degree 2 according to UL/EN 61010-1 |