Paddle-wheel sensor for low-flow rates
The compact low-flow sensor Type 8031 with paddle wheel and Hall sensor is specially designed for use in aggressive and solid-free liquids.
The particular cost attractive measuring principle is based on a local flow velocity measurement. The sensor produces a flow proportional frequency signal which can easily be transmitted and processed.
We recommend here particularly the connection to the Bürkert Universal transmitter Type 8025 (see separate data sheet).
DOWNLOAD CATALOG (ดาวน์โหลดแคตตาล็อก)
TYPE 8031 สามารถใช้ได้ร่วมกับ
General Technical Data
Product properties |
|
Non wetted parts | |
Housing, cover | POM or ECTFE |
Front panel foil | Polyester |
Screws | Stainless steel |
Cable glands | PA |
Female cable plug/male fixed plug M12 male fixed plug |
• Body, contact holders and cable gland in PA • Cable gland seal and flat seal in NBR PA or PA and CuZn, nickel-plated |
Wetted parts |
|
Sensor-fitting body, sensor armature | Brass, stainless steel, PVC, PP or PVDF (depending on S030 version) |
Seal | FKM or EPDM (depending on S030 version) |
Axis | Coated stainless steel or sapphire |
Bearings | POM or Rubin |
Paddle-wheel | POM or ECTFE |
Magnets | ECTFE encapsuled or blank |
Dimensions | Detailed information can be found in chapter “4. Dimensions” on page 4. |
Measuring principle | Paddle wheel |
Measuring range | • 10…100 l/h (2.6…27 gph) • 20…250 l/h (5.3…66 gph) |
K-factor | • 10200 pulse/litre (range 10…100 l/h) • 3400 pulse/litre (range 20…250 l/h) Detailed information can be found in chapter “5.2. Flow characteristic” on page 6. |
Performance data |
|
Measurement deviation | ± 2 % of full scale |
Repeatability | ± 0.8 % of full scale |
Pressure loss | Detailed information can be found in chapter “5.1. Pressure loss diagram” on page 6. |
Electrical data |
|
Operating voltage | 5…24 V DC |
Current consumption | Max. 11 mA at 24 V DC |
Outputs | • Push-pull (complementary output) between V+ (white wire) and signal (green wire) or between GND (brown wire) and signal (green wire) • Frequency: 0…300 Hz |
Medium data |
|
Fluid temperature | 0…80 °C (+ 32…+ 176 °F) |
Fluid pressure | Max. 10 bar (145 PSI) at 20 °C (68 °F) |
Viscosity | 1…10 cSt. |
Process/Port connection & communication |
|
Port connection | • G ¼” • Tube spigot 8/6 mm • Tube spigot 9 mm |
Electrical connections | Cable, 1 m length (3 × 0.14 LiYY) |
Approvals and certificates |
|
Standards Protection class according to IEC/EN 60529 |
IP65 |
CE directives | The applied standards, which verify conformity with the EU Directives, can be found on the EU Type Examination Certificate and/or the EU Declaration of conformity (if applicable). |
Pressure Equipment Directive | Complying with Article 4, Paragraph 1 of 2014/68/EU directive Detailed information on the pressure equipment directive can be found in chapter “3.2. Pressure Equipment Directive” on page 9. |
Certification | UL-Recognized for US and Canada |
Environment and installation | |
Ambient temperature | • Operation: 0…+ 80 °C (+ 32…+ 176 °F) • Storage: – 10…+ 80 °C (+ 14…+ 176 °F) |
*For selecting thecorrect product please refer to the technical data, images and notes for proper use according to the data sheet, or contact Flu-Tech directly.
สอบถามข้อมูลเพิ่มเติม ติดต่อเรา :
02-384-6060 (อัตโนมัติ) [email protected] บริษัท ฟลูเทค จำกัด Flu-tech @flutech.co.th