ROSS Controls® & Concern for Machine Safety
The two go hand in hand. ROSS has been designing and supplying the “industry standards” of safety products for pneumatic energy isolation (LOTO) and control reliable double valves for the metal forming industry for clutch/brake applications and the general manufacturing sector for decades. Even before Federal and State Occupational Safety and Health Administrations (OSHA) existed, ROSS designed and supplied valves for energy isolation and mechanical press clutch/brake control valves that were later widely recognized as aids to companies for regulatory compliance in non-press applications.
These are some of the most safety critical pneumatic valve applications in manufacturing today, and ROSS has been there to help make jobs safer for workers, helping to protect our customers’ investments in machinery, and increase productivity.
Safety Valve Selection Tools
Finding the right valve for your safety application is quick and easy with the ROSS Controls Safety Valve Selection Tools. In your mission to improve workplace safety, protect your machinery investments, and deliver efficient productivity, the user-friendly Selection Tools for hydraulic safety valves, pneumatic safety valves, and press control will help you identify the product you need. Filter products by selecting the application that you’re interested in and then narrow your product results even further by selecting specific product options.
Hydraulic Safety Valves Pneumatic Safety Valves Press ControlROSS® Safety Applications
Energy Isolation
Pneumatic Energy Isolation is achieved with a manually operated valve in a system that stops the further input of a specific energy. Isolation devices for pneumatic systems are generally used in conjunction with a bleed device that is used to dissipate energy that may be downstream of the isolation device. In most pneumatic devices, the isolation device and bleed device are combined into a single component that shuts off the supply of pneumatic energy and also exhausts downstream pneumatic energy from as far downstream as possible.
Safety Exhaust
A safe manufacturing environment must include a healthy respect for the, sometimes dangerous, interactions between man and machinery. This is reflected in the evolution in the once simple and now sophisticated safety-related valves. In pneumatic and hydraulic circuits where the primary concern is the removal of pneumatic or hydraulic energy from a device or system, additional dump or exhaust valves are typically incorporated specifically for this function.
Safe Cylinder Return
ROSS CrossMirror Double Valves provides control reliable cylinder/actuator control resulting in increased safety and savings.
Load Holding
Cylinder applications must take into consideration what happens with the loss of air pressure and how will impact the safety of both man and machine. This is especially important with vertical cylinder applications.
A Global Snapshot of Fluid Power & Safety
Critical-application safety valves are functionally redundant, self-monitoring, and return to a safe position. It is easy to say that “Safety is everyone’s goal,” but what is really meant by that? Sound workplace safety practices can reduce the risk of injury to not only machine operators but to other people such as maintenance technicians; it can also reduce the risk that there is accidently damage to machinery and other company assets, or harm to the environment. Common industry standards acknowledge that there is no such thing as zero risk, while nonetheless providing guidance to machine builders and operators regarding how to take steps to minimize risks. This is commonly referred to as a machine safeguarding. Here’s a snapshot look at some key factors:
Alternative Lock-Nut
The ANSI/ASSE Z244.1 – 2003 (R2008) standard also addresses other lockout techniques, called alternative methods of controls. These systems can save costs and improve machine up time. But alternative methods controls only apply to routine, repetitive tasks that are integral to the production process and are based on risk assessment providing effective personal protection. The machine must still have a standard lockout system for repairs and other tasks.
Alternative methods of controls offer two-time saving advantages. First, it uses a single lock-point (a remote, low-voltage system) that simplifies and speeds lockout, and enhances safety by avoiding the chance of a point being missed. The operator need not travel all around the machine to access various points to lockout or unlock operations. These systems place electrical lockout switches, connected to the control system, at locations that require machine access, and incorporate appropriate safety valves for pneumatic and hydraulic lockout.
The second feature of alternative lockout systems is not all energy needs to be removed. In fact, sometimes removing all the energy creates a more-hazardous condition. This can result in significant time and cost savings when systems contain large volumes of compressed air.
The standard is also useful for tasks that are not routine, repetitive, or integral to production, but require power for, say, troubleshooting a control circuit. The new standard recognizes that there is no such thing as zero risk, and that some risk is present in order to perform certain tasks. In this case, the standard requires that the control system and valve controlling the non-isolated energy be control-reliable, Category-3 or -4.
Risk Reduction
There is no such thing as “zero risk”. Therefore, the standards require that you assess all possible risks, and determine what possible ways can be accomplished for most-effectively reducing those risks. The best approach to risk assessment is as a team. One big change ANSI B11.TR3-2000 brought about is that both the machine manufacturer and user are responsible for performing the assessment for new and rebuilt machines. In the past, machine safety was considered the user’s responsibility. Perhaps the most difficult part is defining the subjective words for the assessment. There are no precise answers, and even the standards differ. Users need to develop their own risk assessment program.
Many companies hold that there are two degrees of injury: minor and major. Minor injuries can be treated with a first aid kit, and anything requiring more extensive care is considered a major injury for risk assessment purposes. When a company uses a risk matrix that leans toward the “better-to-be-safe” side, the first question is, of course, “Will it entail additional expense to eliminate a rare possibility?” But to error on the high side forces the assessment team to look more carefully at each hazard. Often, safety can pay back in machine up time, reduced employee absenteeism, saving the time and cost to investigate an accident, insurance savings, and other hidden costs involved with accidents. Safety is part of a company’s loss-prevention program.
Avoiding using the wrong category valve should be the primary concern when performing a risk assessment. For example, a circuit with a single valve that suffers a broken spring or a sticky spool would have a different fault result than a similar circuit employing a double valve experiencing a broken spring or sticky valve. ANSI B11.TR3-2000 sets the recommended minimum level of control integrity as follows.
- Highest degree of risk reduction – Control systems having redundancy with continuous self-checking to ensure continuous performance.
- High/intermediate risk reduction – Control systems having redundancy with self-checking upon startup.
- Low/intermediate risk reduction – Control systems having redundancy that may be manually checked.
- Lowest degree of risk reduction – Hydraulic or pneumatic devices and associated control system using single-channel configuration.
Path to Safety
The path to fluid power safety can be taken with these 6 steps:
- Identifying tasks and hazards using a Risk Assessment with fluid power considerations.
- Classify these hazards into categories from slight to serious, seldom to frequent, and possible to less possible.
- Reduce the risk by a Risk Reduction Hierarchy from Preferred to Fifth.
- Select the appropriate controls for safeguarding.
- Assess the Residual Risk.
- Record actions taken, monitor results, and document.
Safety Circuit Examples
- Cylinder hazard in 2 directions
- Pinch Points
- Tooling or product damage
- Single Point Lock Out
- Press clutch/brake
- Counterbalance
- Monitored power systems
- Partial de-energization
- Vertical loads
- Cylinder hazard in 2 directions
- Cylinder mid-stroke positioning
- Two-hand control
- Energy Isolation
- EEZ-ON gradual pressure build-up
- Noise reduction
- 2-hand anti-tie-down machine start
- Hose and/or fitting failure
Reference: Ross Controls